background image

English

 3

DANGER

Risk of electric shock.

Never touch the mains plug and the 
socket with wet hands.

Check the power cord with mains plug 
for damage prior to every use. Immedi-
ately have damaged power cord re-
placed by an authorised customer ser-
vice / electrician. Do not operate an ap-
pliance if the power cord is damaged.

All current-conducting parts in the work-
ing area must be protected against jet 
water.

The mains plug and the coupling of an 
extension cable must be watertight and 
must never lie in water. Moreover, the 
coupling may never lie on the ground. 
The use of cable reels that ensure that 
the sockets are at least 60 mm above 
the ground is recommended.

Make sure that the power cord or exten-
sion cable is not damaged by running 
over, pinching, dragging or the like. Pro-
tect the power cords from heat, oil, and 
sharp edges.

Turn off the appliance and remove the 
mains plug prior to any care and main-
tenance works.

Repair work and work on the electrical 
components may only be performed by 
an authorised customer service.

WARNING

The appliance may only be connected 
to an electric supply that has been in-
stalled by an electrician in accordance 
with IEC 60364.

The appliance may only be connected 
to alternating current. The voltage must 
correspond with the type plate of the 
appliance.

For safety reasons, we recommend that 
you operate the appliance only via a re-
sidual current device (max. 30 mA).

Safety class I - Appliances may only be 
connected to sockets with proper earth-
ing. 

An unsuitable electrical extension cable 
can be hazardous. Only use an electri-
cal extension cable which has been ap-
proved and labelled for this purpose 
and has an adequate cable cross-sec-
tion outdoors: 1 - 10 m: 1.5 mm

2

10 - 30 m: 2.5 mm

2

Always fully unreel the extension cable 
from the cable drum.

DANGER

The user must use the appliance as in-
tended. The person must consider the 
local conditions and must pay attention 
to other persons in the vicinity when 
working with the appliance.

Check important components, such as 
high-pressure hose, hand spray gun 
and safety installations, for damage pri-
or to every operation. Immediately re-
place damaged components. Do not 
operate appliance with damaged com-
ponents.

High-pressure jets can be dangerous if 
improperly used. The jet may not be di-
rected at persons, animals, live electri-
cal equipment or at the appliance itself.

The high-pressure jet must not be di-
rected at other persons or the user him-
/herself to clean clothing or footwear.

Vehicle tyres/tyre valves are suscepti-
ble to damage from the high-pressure 
jet and may burst. The first indication for 
this is a discolouration of the tyre. Dam-
aged vehicle tyres/tyre valves are peril-
ous. Keep a minimum jet distance of 
30 cm during cleaning!

WARNING

Do not use the appliance when there 
are other persons around unless they 
are also wearing protective clothing.

The appliance must not be operated by 
children or persons who have not been 
instructed accordingly.

Electric components

Safe handling

Summary of Contents for K 5 Premium

Page 1: ...K 5 Premium English 59672370 11 16...

Page 2: ...tional cleaning agents with accessories replacement parts and cleaning agents approved by K RCHER Please observe the infor mation accompanying the cleaning agents DANGER Pointer to immediate danger wh...

Page 3: ...ce max 30 mA Safety class I Appliances may only be connected to sockets with proper earth ing An unsuitable electrical extension cable can be hazardous Only use an electri cal extension cable which ha...

Page 4: ...ents as they corrode the materials used on the appliance Keep packaging films away from chil dren there is a risk of suffocation WARNING According to applicable regulations the appliance must never be...

Page 5: ...against frost Safety Devices Appliance switch Lock trigger gun Overflow valve with pressure switch Motor protection switch Environmental protection The packaging material can be recy cled Please arran...

Page 6: ...f your appliance is illustrated on the packaging Check the contents of the appliance for completeness when unpacking In the event of missing accessories or any transport damage please contact your dea...

Page 7: ...ches 13 mm Minimum length 7 5 m Mount loose parts delivered with appliance prior to start up Illustrations on Page 14 Illustration Install the transport wheels Attach the wheel caps Illustration Place...

Page 8: ...made of metal with aquas top can damage the pump Please use plastic couplings or K RCHER brass cou plings Attach the water supply hose to the coupling on the water connection Connect the water supply...

Page 9: ...hered to especially the instructions regarding personal protective equipment Most K RCHER detergents can be bought ready to use in a Plug n Clean detergent bottle Note Detergent can only be added when...

Page 10: ...r gun Turn off the appliance 0 OFF Disconnect the mains plug from the socket Turn off tap Press the lever on the trigger gun to re lease any remaining pressure in the system Lock the lever on the trig...

Page 11: ...Completely drain appliance and ac cessories and protect them against frost To avoid damage Detach the appliance from the water supply Detach spray lance from the trigger gun Turn on the appliance I O...

Page 12: ...ray lance Check water supply for adequate deliv ery rate Pull out the sieve in the water connec tion using flat nose pliers and clean un der running water Appliance ventilation Switch the appli ance o...

Page 13: ...orized Customer Service centre Please submit the proof of purchase Addresses can be found under www kaercher com dealersearch Subject to technical changes Accessories and Spare Parts Warranty Technica...

Page 14: ...14 English Illustration...

Page 15: ...English 15 Illustration...

Page 16: ......

Page 17: ...Alfred K rcher GmbH Co KG Alfred K rcher Str 28 40 71364 Winnenden Germany Tel 49 7195 14 0 Fax 49 7195 14 2212 http www kaercher com dealersearch...

Page 18: ...15...

Page 19: ...14...

Page 20: ...13 220 1 50 V Hz 2 1 kW IP X5 I 0 8 MPa 40 C 10 l min 0 5 12 5 MPa 14 5 MPa 7 5 l min 8 3 l min 0 0 3 l min 20 N 349 mm 426 mm 878 mm 15 3 kg...

Page 21: ...12 Vario Power Mix Plug n Clean www kaercher com www kaercher com dealersearch...

Page 22: ...11 I ON 0 OFF 0 OFF I ON...

Page 23: ...10 5 0 OFF 0 OFF Plug n Clean...

Page 24: ...9 30 90 I ON K RCHER Plug n Clean Vario Power Mix Plug n Clean Plug n Clean...

Page 25: ...8 KARCHER 059 4 730 K RCHER KARCHER 4 440238 I ON...

Page 26: ...7 1 2 3 4 5 6 7 8 9 10 Plug n Clean 11 12 13 14 Plug n Clean 15 16 17 18 19 Vario Power Min Max Mix 20 1 2 13 7 5 14 PH2 PH2...

Page 27: ...6...

Page 28: ...5 REACH www kaercher com REACH...

Page 29: ...4 EN 12729 Typ BA FFP 2...

Page 30: ...3 IEC 60364 30 I 1 10 m 1 5 mm2 10 30 m 2 5 mm2 30...

Page 31: ...2 KARCHER 60 2 5 6 7 8 9 10 10 11 11 12 12 13 15...

Page 32: ...K 5 Premium 59672370 11 16...

Reviews: