English

Only trigger the high-pressure jet at the 
high-pressure gun if the T-Racer is lo-
cated on the surface to be cleaned.

There must be no persons in the imme-
diate vicinity of the cleaning head.

Beware of the recoil force! Ensure a 
stable position and firmly hold the high-
pressure gun with the extension tube or 
the handle.

Switch off the high-pressure cleaner 
when you finish cleaning. If you are us-
ing the T-Racer then disconnect the 
same from the high-pressure gun.

Maximum water temperature 60°C 
(please observe the instructions of your 
high-pressure cleaner).

Danger!

Do not hold under the edge of the 
T-Racer when it is on!

When unpacking the product, make sure 
that no accessories are missing and that 
none of the package contents have been 
damaged. If you detect any transport dam-
ages please contact your dealer. 

See page 11, illustration 

1 Casing
2 Bayonet connection with safety cover
3 Extension tube
4 High pressure nozzle
5 Rotor arm

The T-Racer is ideally suited for the cleaning 
of floor and wall surfaces made of different 
materials, such as wood, plastic, concrete, 
tiles, and natural stone. Use the T-Racer ex-
clusively in your private household.

Note

: Always use Kärcher water filter (or-

der no. 4.730-059.0) during suction opera-
tions of the high-pressure cleaner.

Fasten the T-Racer to the high-pressure 
gun using the extension pipe.

Illustration 

1 Press the extension tube into the bayo-

net connection of the high-pressure 
gun, then turn by 90° until it locks into 
place.

2 Tighten the safety cover.
Repeat this process even for the other con-
nections.

Outdoor surfaces should be swept be-
fore the T-Racer is used to avoid dam-
aging the high-pressure nozzles.

The T-Racer is not suited for scouring 
or scrubbing!

Caution

Illustration 

Do not run over free-standing corners!

Fasten the T-Racer directly to the high-
pressure gun. 
1 Press the bayonet connection of the T-

Racer into the connection of the high-
pressure gun, then turn by 90° until it 
locks into place.

2 Tighten the safety cover.

Caution

Illustration 

Always hold the high-pressure gun with 
both the hands while cleaning the walls.

Safety instructions

Symbols on the machine

Description of the Appliance

Proper use

Application

Cleaning floor surfaces

Tips for cleaning

Cleaning wall surfaces

Summary of Contents for K 3.170 T 50

Page 1: ...59643050 06 11 K 3 170 T 50 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them...

Page 2: ...integrated sieve 10 Mains cable with mains plug 11 Bearing wheel 12 Coupling element for water connection 13 Trigger gun 14 Lock trigger gun 15 High pressure hose 16 Key to detach the high pressure ho...

Page 3: ...terials that can be recycled Please arrange for the proper recycling of old appliances Please dispose your old appli ances using appropriate collection sys tems Notes about the ingredients REACH You...

Page 4: ...y flammable liquids Never draw in fluids containing solvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is highly inflammable exp...

Page 5: ...appliance may only be connected to alternating current The voltage must correspond with the type plate on the appliance For safety reasons we recommend that you operate the appliance only via a earth...

Page 6: ...water supply never directly to the appli ance Observe regulations of water supplier For connection values see type plate tech nical data Use a fibre reinforced water hose not included with a standard...

Page 7: ...r gun and spray lance firmly Unlock the lever on the trigger gun Pull on the lever of the trigger gun the device will switch on Note Release the lever of the trigger gun the device will switch off aga...

Page 8: ...lever on the trigger gun Turn off the appliance 0 OFF Turn off tap Detach the appliance from the water supply Press the lever on the trigger gun to re lease any remaining pressure in the system Lock...

Page 9: ...r Turn off the appliance and remove the mains plug prior to any care and mainte nance work Repair works may only be performed by the authorized customer service Pull on the lever of the trigger gun th...

Page 10: ...karcher co nz Appliance is leaking No detergent infeed Technical specifications Electrical connection Voltage 1 50 60 Hz 220 240 V Connected load 1 6 kW Protection class IP X5 Protective class II Main...

Page 11: ...English 11 T Racer T 50...

Page 12: ...of different materials such as wood plastic concrete tiles and natural stone Use the T Racer ex clusively in your private household Note Always use K rcher water filter or der no 4 730 059 0 during su...

Page 13: ...all the high pressure nozzles Illustration 1 Remove the clip 2 Pull out the high pressure nozzle 3 Rinse the high pressure nozzle with clean water replace if necessary 4 Insert the nozzle 5 Re insert...

Page 14: ......

Page 15: ......

Page 16: ...www karcher co nz www karcher com au...

Reviews: