6
English
Mount loose parts delivered with appliance
prior to start-up.
Illustrations on Page 2
Illustration
Insert the transport wheels and lock
them.
Illustration
Insert the transport handle and screw
in.
Illustration
Push the high pressure hose into the
trigger gun until it locks audibly.
Note:
Make sure the connection nipple
is aligned correctly.
Check the secure connection by pulling
on the high pressure hose.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
Observe regulations of water supplier.
For connection values, see type plate/tech-
nical data.
Use a fibre-reinforced water hose (not
included) with a standard coupling.
(Minimum diameter 1/2 inch (13 mm),
minimum length 7.5 m).
Screw the supplied coupling element to
the water connection on the appliance.
Push the water supply hose onto the
coupling unit, then connect it to the wa-
ter supply.
KÄRCHER recommends using the suction
hose accessory (sold separately) Order no.
9.505-779.0.
STEP 1:
Connect the suction hose to the water
inlet on the pressure cleaner and drop
the other end into a bucket.
Tip
: If you are not using this accessory, coil
a hose into the bucket and ensure that you
only use a standard hose clamp to connect
to the pressure washer.
CLICK FITTINGS MUST NOT BE USED!
STEP 2:
Fill up your bucket with water.
Operation
Before Startup
Water supply
Water supply from mains
How to draw water from a bucket when
using a KÄRCHER Pressure Cleaner