background image

English

 9

Danger

Turn off the appliance and remove the 
mains plug prior to any care and mainte-
nance work.

Prior to longer periods of storage, e.g. in 
the winter:

Î

Remove filter from suction hose for de-
tergent and clean under running water.

Î

Pull out the sieve in the water connec-
tion using flat-nose pliers and clean un-
der running water.

The appliance is maintenance-free.

Use only original KÄRCHER spare parts. 
You will find a list of spare parts at the end 
of these operating instructions.

Special accessories expand the possibili-
ties of using your appliance. Please contact 
your KÄRCHER dealer for further informa-
tion.

You can rectify minor faults yourself with 
the help of the following overview. 
If in doubt, please consult the authorized 
customer service.

Danger

Turn off the appliance and remove the mains 
plug prior to any care and maintenance work.
Repair works may only be performed by the 
authorized customer service.

Î

Pull on the lever of the trigger gun; the 
device will switch on.

Î

Check whether the voltage indicated on 
the type plate corresponds to the volt-
age of the mains supply.

Î

Check the mains connection cable for 
damages.

Î

Appliance ventilation: Switch the appli-
ance on with the high-pressure hose 
detached and operate (max. 2 minutes) 
until the water exits the high-pressure 
connection without bubbles. Switch off 
appliance and reconnect high-pressure 
hose.

Î

Check the water supply.

Î

Pull out the sieve in the water connec-
tion using flat-nose pliers and clean un-
der running water.

Î

Clean high-pressure nozzle: Remove 
dirt and debris from the nozzle bore, us-
ing a needle and rinse through with wa-
ter from the front.

Î

Check water flow quantity.

Î

Slight leakage from the appliance pump 
is normal. If the leakage increases con-
tact the authorized customer service.

Î

Detach spray lance from the trigger 
gun. Work only with the trigger gun.

Î

Clean the detergent suction hose filter.

Î

Check the detergent suction hose for 
kinks.

Maintenance and care

Care

Maintenance

Spare parts

Special accessories

Troubleshooting

Appliance is not running

Pressure does not build up in the appliance

Strong pressure fluctuations

Appliance is leaking

No detergent infeed

Summary of Contents for K 2.080

Page 1: ...R egister and w in w w w kaercher com Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them K 2 080 59639110 08 10...

Page 2: ...can be recycled Please arrange for the proper recycling of old appliances Please dispose your old appli ances using appropriate collection sys tems Notes about the ingredients REACH You will find cur...

Page 3: ...nection cable 6 Storage for spray lance 7 Storage for high pressure hose 8 Mains cable with mains plug 9 Connection for water supply with filter 10 Coupling element for water connection 11 Trigger gun...

Page 4: ...lvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is highly inflammable explosive and poi sonous Do not use acetone undiluted aci...

Page 5: ...pe plate on the appliance For safety reasons we recommend that you operate the appliance only via a earth leakage circuit breaker max 30 mA Cleaning operations which produce oily waste water e g engin...

Page 6: ...e type plate tech nical data Use a fibre reinforced water hose not included with a standard coupling Minimum diameter 1 2 inch 13 mm minimum length 7 5 m Screw the coupling element supplied to the wat...

Page 7: ...em For normal cleaning tasks Not suitable for use with detergents Please use exclusively K RCHER deter gents and care products to carry out the re spective cleaning task as these were specifically dev...

Page 8: ...Caution In order to prevent accidents or injuries keep in mind the weight of the appliance when selecting a storage location for it see Specifications Prior to extended storage periods as dur ing the...

Page 9: ...will switch on Check whether the voltage indicated on the type plate corresponds to the volt age of the mains supply Check the mains connection cable for damages Appliance ventilation Switch the appli...

Page 10: ...sumption 6 A Protection class IP X5 Protective class II Mains fuse slow blow 10 A Water connection Max feed temperature 40 C Max feed pressure 1 2 MPa Min feed volume 8 I min Performance data Working...

Page 11: ...English 11 Spare Parts...