Wear protective clothing and safety 
goggles to protect against splash back 
containing water or dirt.

Caution

„

In case of extended downtimes, switch 
the appliance off at the main switch / ap-
pliance switch or remove the mains 
plug.

„

Do not operate the appliance at temper-
atures below 0 °C.

„

Observe a distance of at least 30 cm 
when using the jet to clean painted sur-
faces to avoid damaging paintwork.

„

Never leave the appliance unattended 
when it is in operation.

„

Make sure that the power cable or ex-
tension cables are not damaged by run-
ning over, pinching, dragging or similar. 
Protect the power cable from heat, oil, 
and sharp edges.

„

All current-conducting parts in the work-
ing area must be protected against jet 
water.

„

The appliance may only be connected 
to an electrical supply which has been 
installed in accordance with IEC 60364.

„

The appliance may only be connected 
to alternating current. The voltage must 
correspond with the type plate on the 
appliance.

„

For safety reasons, we recommend that 
you operate the appliance only via a 
earth-leakage circuit breaker (max. 
30 mA).

„

Cleaning operations which produce oily 
waste water, e.g. engine washes, un-
derbody washes, may only be carried 
out using washing stations equipped 
with an oil separator.

Caution

Safety devices protect the user and must 
not be modified or bypassed.

The appliance switch prevents unintention-
al operation of the appliance.

This lock locks the lever of the trigger gun 
and prevents the inadvertent start of the ap-
pliance.

The overflow valve prevents the permissi-
ble working pressure from being exceeded. 
If the lever on the trigger gun is released 
the pressure switch turns off the pump, the 
high-pressure jet is stopped. If the lever is 
pulled the pump is turned on again.

Caution

Create stability for the appliance prior to all 
work on or with the appliance to prevent ac-
cidents or damage.

– The stability of the appliance is warrant-

ed when it is placed onto an even sur-
face.

Safety Devices

Power switch

Lock trigger gun

Overflow valve with pressure switch

Prerequisites for the appliance's 

stability

Summary of Contents for K 2.080

Page 1: ...R egister and w in w w w kaercher com Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them K 2 080 59639110 08 10...

Page 2: ...can be recycled Please arrange for the proper recycling of old appliances Please dispose your old appli ances using appropriate collection sys tems Notes about the ingredients REACH You will find cur...

Page 3: ...nection cable 6 Storage for spray lance 7 Storage for high pressure hose 8 Mains cable with mains plug 9 Connection for water supply with filter 10 Coupling element for water connection 11 Trigger gun...

Page 4: ...lvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is highly inflammable explosive and poi sonous Do not use acetone undiluted aci...

Page 5: ...pe plate on the appliance For safety reasons we recommend that you operate the appliance only via a earth leakage circuit breaker max 30 mA Cleaning operations which produce oily waste water e g engin...

Page 6: ...e type plate tech nical data Use a fibre reinforced water hose not included with a standard coupling Minimum diameter 1 2 inch 13 mm minimum length 7 5 m Screw the coupling element supplied to the wat...

Page 7: ...em For normal cleaning tasks Not suitable for use with detergents Please use exclusively K RCHER deter gents and care products to carry out the re spective cleaning task as these were specifically dev...

Page 8: ...Caution In order to prevent accidents or injuries keep in mind the weight of the appliance when selecting a storage location for it see Specifications Prior to extended storage periods as dur ing the...

Page 9: ...will switch on Check whether the voltage indicated on the type plate corresponds to the volt age of the mains supply Check the mains connection cable for damages Appliance ventilation Switch the appli...

Page 10: ...sumption 6 A Protection class IP X5 Protective class II Mains fuse slow blow 10 A Water connection Max feed temperature 40 C Max feed pressure 1 2 MPa Min feed volume 8 I min Performance data Working...

Page 11: ...English 11 Spare Parts...

Page 12: ......

Reviews: