3
DANGER
Risk of fatal injuries on account of electric
voltage! Required electrical work must only
be performed by an electrical specialist.
– The socket must be secured through a
residual current device (RCD) with a
triggering current of 30 mA.
– This socket must be located close to the
work station so that the plug can be
pulled immediately in case of an emer-
gency.
– The interior cleaner is standard
equipped with spray nozzles that are
designed for a flow rate of 900-1200 l/h
(15-20 l/min) (nozzle set no. 2).
– If the high-pressure pump has a differ-
ent flow rate, the nozzles must be re-
placed as per the table.
– The minimum pressure value of the reg-
ulating valve must be set prior to switch-
ing on the high-pressure pump. This
way, the interior cleaner will not be ex-
posed to pressure peaks when switch-
ing on.
1 Suction nozzle
2 Hexagon socket wrench
3 Water output stub
Unscrew the water output stub.
Unscrew the suction nozzle in the hole
using the hexagon socket wrench in-
cluded in the nozzle set.
Screw on the new nozzle.
Coat the thread of the water output stub
with Loctite 243 or use Teflon tape.
Screw on the water output stub.
Check water output stub to see it is
leak-proof.
1 Spray nozzle
2 Cleaning head
3 Hexagon socket wrench
Unscrew the spray nozzles using the
hexagon socket wrench included in the
nozzle set.
Screw on the new nozzles.
DANGER
Risk of injury on account of the escaping
water jet that could be hot!
–
Only use the interior cleaner in closed
containers.
–
Only insert the interior cleaner into a
container or switch it into another con-
tainer while the separate high pressure
pump and internal drive are turned off.
DANGER
Risk of electric shock!
–
Using the attached Velcro parts, posi-
tion the power supply so that is protect-
ed from water spray.
–
Protect the extension cable from spray
water.
Technical specifications
BC 14/12
Order No.
2.112-020
Max. flow rate
l/h (l/
min)
1400 (23,3)
Max. temperature of
the cleaning liquid
°C
80
Max. operating over-
pressure
MPa
(bar)
14 (140)
Operating pressure
with nozzle set no. 2
MPa
(bar)
12 (120)
Voltage
V
115-240
Current type
--
1~
Frequency
Hz
50-60
Electro motor
VDC
12
Rated power
W
40
Type of protection
--
IP 55
Functional speed -
drive
1/min
62
High pressure con-
nection
mm
M22x1,5
Water output
Inch
G 1/2
Minimum container
opening
mm
40
Total length
mm
1200
Max. immersion
depth
mm
900
Typical operating
weight
kg
4,8
Ambient tempera-
ture
°C
+2...+40
Specifications sheet
Start up
Note
We recommend using a dirt filter in the
high-pressure line, however, the sieve
should be cleaned regularly.
Electric drive
Replace nozzles
Nozzle
set no. 1
Nozzle
set no. 2
Nozzle
set no. 3
Flow rate l/h
(l/min)
600-900
(10-15)
900-
1200
(15-20)
1200-
1500
(20-25)
Colour of
the suction
nozzle
yellow
green
blue
Colour of
the spray
nozzle
blue
red
purple
Suction nozzle
Spray nozzles
Operation
Note
Try to set up the interior cleaner in the
center of an area.
10
EN
Summary of Contents for BC 14/12
Page 2: ...2...
Page 61: ...4 2 3 mm SPRAY SUCTION K rcher Kaercher 1 2 3 4 5 17 mm 36 30 61 EL...
Page 71: ...4 2 3 SPRAY Position SUCTION Position K rcher K rcher 1 2 3 4 5 17 36 71 RU...
Page 116: ...4 2 3 SPRAY SUCTION K rcher Karcher 1 2 3 4 5 17 36 116 BG...
Page 136: ...4 2 3 SPRAY Pos t on SUCTION Pos t on K rcher K rcher 1 2 3 4 5 17 36 136 UK...
Page 138: ......
Page 139: ......