13
Pump removal procedure
Remove the recovery tank from the machine exposing the
pump access cover. Using the T-20 Torx driver remove the 3
screws holding the cover in place.
To remove the pump push the gray ring in towards the elbow
and pull on the hose at the same time releasing it from the
fitting. Turn the lift the pump and turn it slightly upward then lift
it out. Remove the other hose from the pump.
When reinstalling the
pump, care must be taken
to place the holes in the
rubber shock mounts onto
the pins in the housing
(left).
Before placing the pump
into the housing insert the
hose into the inlet side of
the pump (right).