– 6
The shoulder support (2.639-251.0) should
be used to prevent injuries and to make
work easier at recoil pressures > 150 N.
The appliance is equipped with the follow-
ing nozzles:
– Power nozzle, 15° spray angle
High pressure flat stream (15°) for large
areas of contamination.
The working pressure can be read from
the manometer.
Note:
Always direct the high-pressure jet at the
object to be cleaned from a distance to
avoid damage from high pressure.
Release the lever on the trigger gun.
Use the safety catch to secure the
handgun lever.
Store the hand spray gun and spray
pipe in the accessory mount.
The working pressure can be changed by
using different high-pressure nozzles.
Select a nozzle from the table above.
Unscrew the union nut from the spray
lance.
Replace nozzle.
Screw on and tighten the union nut.
Note:
This method of pressure adjustment al-
ways means that the full flow rate of 1800 l/
h is always available.
Release the lever on the trigger gun.
Set the appliance switch to "0".
Shut off water supply.
Activate hand spray gun until device is
pressure less.
Use the safety catch to secure the
handgun lever.
Remove the water inlet hose from the
appliance.
Pull out the mains plug.
Stow away the mains cable, the high-
pressure hose and accessory at the ap-
pliance.
몇
WARNING
Risk of damage! Freezing water in the ap-
pliance can destroy parts of the appliance.
Store the appliance in a heated room dur-
ing winter or empty it. During longer breaks
in operation, it is advisable to pump in anti-
frost agents into the appliance.
Screw off water supply hose and high
pressure hose.
Blow through machine with com-
pressed air.
Note:
Observe handling instructions of the anti-
freeze agent manufacturer.
Pump in conventional frost protection
agents through the appliance.
A certain corrosion protection is achieved
with this as well.
몇
CAUTION
Risk of personal injury or damage! Mind the
weight of the appliance during transport.
Pull the actuation lever of the parking
brake all the way to the back.
Power nozzle
Interrupting operation
Changing working pressure
Pressure
MPa (bar)
Nozzle
size
Order number
Flat jet nozzles
50 (500)
15060
5.765-263.0
35 (350)
15075
2.113-073.0
25 (250)
15095
2.113-075.0
15 (150)
15120
2.113-077.0
Detail nozzles
50 (500)
060
5.765-264.0
35 (350)
075
2.113-074.0
25 (250)
095
2.113-076.0
15 (150)
120
2.113-078.0
Finish operation
Frost protection
Drain water
Flush device with anti-freeze agent
Transport
Driving