background image

KP2000 User Manual Version 1.0-EN 

9 of 33 

 

Installation 

Connect Scanner to computer 

 

 

 

1.

 

Switch Off the Computer 

2.

 

Refer to the below pictures, connect the USB Cable to the computer  

3.

 

Ensure tha all the connection are secure  

4.

 

Switch On the Computer. If installation is correct the LED 

 will lights Up and the Buzzer ⑤ will emit a beep. 

 

 

Disconnect Scanner from Computer 

 

1.

 

Switch Off the computer and unplug the USB Cabe 

 

Restore factory default parameters 

To restore the factory default parameters read the below barcodes in sequence 
 

 

 

Start Configuration((+SETF)) 

 

 

Set All default((+RETF)) 

 

 

End Configuration((+ENDF)) 

 

Programming instruction and example 

To set the device just scan the related code. Example 

 

 

Start Configuration((+SETF)) 

 

 

Set All US Keyboard((+B2A)) 

 

 

End Configuration((+ENDF)) 

 
For more and detailed information howmto configure the scanner please refere to the 

Settings chapter

 

 

Summary of Contents for KP2000

Page 1: ...KP2000 User Manual Version 1 0 EN www kaptur id com KP2000 Linear CCD Barcode Scanner User Manual ...

Page 2: ...e contents and the form of this document as well as to modify the product specifications at any time The information contained in this document is property of Trovi Technology to whom all rights are reserved No part of this document may be photocopied reproduced or translated in another language without express written consent by Techsigno srl Trovi Technology Co LTD 410 4th floor Sunrise Industry...

Page 3: ...0 Power on alert 10 LED indication 10 Beeper indication 10 USB interface 10 USB device type 10 Keyboard layout 10 Scan mode 10 Trigger Mode 10 Continuos Mode 10 Decode illumination and aim pattern 10 Vertical centering read 10 Setting 11 System Information 11 Interface configuration 11 Language Keyboard Setting 12 Select Terminator 12 Add Prefix Suffix 13 Scan Reading Mode 14 Buzzer Setup 14 Symbo...

Page 4: ... 0 EN Technical specifications 24 Supported Barcode Defaultsettingfor each barcode 25 Troubleshooting 26 Maintenance 27 Assembling the stand 28 Installing the Driver for USB VCOM Mode 29 Disable digital signature check 29 Test barcode 33 ...

Page 5: ...or return it to the dealer Do not dispose of these products in unsorted municipal refuse Return the product to an authorized collection center to avoid damage to the environment or human health caused by uncontrolled disposal of waste and to promote the sustainable re cycling of materials Improper disposal of the product by the user entails the application of administrative sanctions provided by l...

Page 6: ...rs are indicated with an H suffix example or in form 0x Example 2A3BH or 0x2A3B Symbology used in the definitions table Symbol Text Definition Symbol Text Description I Input X Output I O Bi Directional Passive Model specific Depends on the device NC Not connected Reserved User reserved for Kaptur must remained disconnected Signal active low Notified potential danger or possible malfunctioning Ins...

Page 7: ...Ø Serial number Ø Detailed and complete description of the malfunction Ø Your company s information Ø The reference person within your company In response to your mail you will receive an RMA number Returned Material Authorization which authorizes the material s return The device must be returned in a protective antistatic bag and adequately packaged to ensure that the product is well protected du...

Page 8: ...ed Packaging Information Inside the standard packaging you will find A Barcode Reader a flexible stand optional the Quick Guide Part of the scanner Use a piece of dry and soft cloth when cleaning the scanner Be carefull and do not scrap the reading windows ...

Page 9: ...nnect Scanner from Computer 1 Switch Off the computer and unplug the USB Cabe Restore factory default parameters To restore the factory default parameters read the below barcodes in sequence 1 Start Configuration SETF 2 Set All default RETF 3 End Configuration ENDF Programming instruction and example To set the device just scan the related code Example 1 Start Configuration SETF 2 Set All US Keybo...

Page 10: ...orts different national keyboard layouts Commonly an appropriate encoding system must be selected Please refer to Settings to configure and for details Inter character delay This delay is inserted after each data character transmitted By selecting the user can change the output speed of the scanner to match the speed of the host USB communication port Ask factory for this settings Scan mode Trigge...

Page 11: ...F Note The default factory settings is indicated with Default System Information Start Configuration SETF Set All default RETF End Configuration ENDF Interface configuration The scanner support different interface USB HID and USB Virtual COM Start Configuration SETF USB HID A1C USB Virtul COM A1D End Configuration ENDF When the scanner is configured in USB Virtual COM the Driver have to be install...

Page 12: ...figuration SETF USA B2A Default Italian B2B Spanish B2C French B2D Germany B2G Japan B2F Portugal B2G End Configuration ENDF Select Terminator It is possible to add a terminator at the and of the trasmission of the code readed The selection can be None Return CR TAB Return Line Feed CR LF Start Configuration SETF None B9A CR B9B Default TAB B9C ESC B9D End Configuration ENDF ...

Page 13: ... indicate below 1 Scan the barcode Start Configuration 2 Check the ASCII table and get the ASCII Code for the Character to add 3 Scan the barcode of ASCII 4 Scan End Configuration Start Configuration SETF ADD Prefix E4A ADD Suffix E5A End Configuration ENDF Example Add character as prefix On the ASCII Table the character is equal to 2B 1 Start Configuration SETF 2 Add Prefix 3 2 4 B 3 End Configur...

Page 14: ...gger In this configuration is not necessary press the trigger to read a code Contin Time Out Off E1F In this configurationthe scanner star reading in continuos mode when the trigger button is pressed The scanner stop after for a time ouf after the last good read In this configuration is not necessary press the trigger to read a code Continuos E1H In this configurationthe scanner star reading in co...

Page 15: ...guration SETF UPC A Disabled F1A Enable Disable UPC A Code UPC A Enabled F1B Default Convert OFF F3A Default UPC A Convert to EAN 13 Convert ON F3B Trasmit Check OFF F4A UPC A Trasmit Check Character Trasmit Check ON F4B Default End Configuration ENDF UPC A Add On 2 or 5 Digit Start Configuration SETF None F8A Default Enable Disable UPC A Add On 2 digit F8B Number of Digit 5 digit F8C 2 or 5 digit...

Page 16: ...ert to UPC A ON G3B OFF G4A UPC E Trasmit Check Character ON G4B Default OFF G7A Default UPC E Truncate Leading Zero ON G7B End Configuration ENDF UPC E Add On 2 or 5 Digit Start Configuration SETF None G8A Enable Disable UPC E Add On 2 of 5 2digit G8B Number of Digit 5digit G8C 2 or 5 digit G8D Number of Digit AUTO_Enable G8E End Configuration ENDF ...

Page 17: ...e ON H1B Default OFF H3A EAN 13 Trasmit Check Character ON H3B Default End Configuration ENDF EAN 13 Add On 2 or 5 Digit Start Configuration SETF None H6A Default Enable Disable EAN 13 Add On 2 or 5 2 Digit H6B Number of Digit 5 Digit H6C 2or 5 Digit H6D Number of Digit AUTO_Enable H6E End Configuration ENDF ...

Page 18: ...e ON I1B Default OFF H3A EAN 8 Trasmit Check Character ON I3B Default End Configuration ENDF EAN 8 Add On 2or 5 Digit Start Configuration SETF None I6A Default Enable Disable EAN 13 Add On 2 or 5 2 digit I6B Number of Digit 5 digit I6C 2 or 5 digit I6D Number of Digit AUTO_Enable I6E End Configuration ENDF ...

Page 19: ...3B 01H 50H J6A Code 39 Min Length Default 01 Code 39 Max Length Default 50 01H 50H J7A Std Code39 J9A Default Full ASCII Code39 J9B Trioptic CODE39 J9C End Configuration ENDF Codabar Start Configuration SETF OFF K2A Enable Disable Codabar ON K1B Default OFF K4A Default Codabar Trasmit Check Character ON K4B OFF K9A Codabar Trasmit End Character ON K9B Default End Configuration ENDF ...

Page 20: ... L4B End Configuration ENDF Code 128 Start Configuration SETF OFF M1A Enable Disable Code 128 ON M1B Default OFF M4A Default Code128 Trasmit Check Character ON M4B End Configuration ENDF Interleaved 2 of 5 Start Configuration SETF OFF N1A Enable Disable Interleaved 2 of 5 ON N1B Default OFF N4A Interleraved Trasmit Check Character ON N4B Default End Configuration ENDF ...

Page 21: ... Version 1 0 EN 21 of 33 Code 32 Start Configuration SETF OFF S1A Default Enable Disable Code 32 ON S1B OFF S4A Default Code32 Trasmit Check Character ON S4B OFF S8A Default Code32 Trasmit A ON S8B End Configuration ENDF ...

Page 22: ... d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o DEL To have the right code select the column and that the row Example To value of the A is 41 Column 4 Row 1 the value of is 2B Column 2 Row B Use the ASCII Code Value to set the value ...

Page 23: ...KP2000 User Manual Version 1 0 EN 23 of 33 ASCII Code Value 0 A 1 B 2 C 3 D 4 E 5 F 6 7 Y 8 N 9 ...

Page 24: ...UPC A UPC E EAN 13 EAN 8 ISBN ISSN Code 39 Code 38 Full Ascii Code 32 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code 128 UCC ENA 128 Code 93 Code 11 MSI Plessey Indicator Beeper LED Interface supported USB Keyboard USB virtual COM Dimensions Height x Width Depth 90 70 164mm Weight 190g without cable Cable Straight 2 0m Case material PC TPU Temperature Operating 0 to 40 C Storage 4...

Page 25: ...t transmission Min code length UPC A 12 1 UPC E 8 1 EAN 13 13 1 EAN 8 8 1 Code 39 1 Interleaved 2 of 5 6 Codabar 6 Code 128 3 Code 93 3 Code 32 16 1 Notes 1 Fixed length barcodes 2 The settings for GS1 DataBar Truncated and GS1 DataBar must be the same The following barcodes are supported but non enabled as factory default Ask factory for settings CODE 32 CODE 11 MSI Plessey China Post Code Matrix...

Page 26: ...e Be sure the scanner is programmed to read the type of bar code you are scanning Distance between scanner and bar code is incorrect Move the scanner closer to or further from the bar code Scanned data is incorrectly displayed on the host Scanner is not programmed to work with the host Check scanner host type parameters or editing options Be sure proper host is selected For RS 232 ensure the scann...

Page 27: ...y window may affect scanning accuracy 2 Do not allow any abrasive material to touch thewindow 3 Remove any dirt particles with a dampcloth 4 Wipe the window using a tissue moistened withwater 5 Do not spray water or other cleaning liquids directly into thewindow 6 Use a piece of soft and dry cloth when cleaning thescanner ...

Page 28: ...tand on the working station with right screw for the material of the working station ex Wood Ensure the flexible stand is fixed and stable Screws are not included 3 Adhesive tape mounting Peel the paper liner off one side of each piece of tape and place the sticky surface over each of the three rectangular tape holders Peel the paper liner off the exposed sides of each piece of tape and press the ...

Page 29: ...using right click on This PC Properties System System type and follow the on screen installation procedure If you are using Windows 8 8 1 or 10 you must disable the digital signature check option of your Operating System before the launch of the executable this will require a reboot See Disable Digital Signature Check chapter 4 Plug the Kaptur device to your PC and scan the Enable USB Virtual COM ...

Page 30: ...30 of 33 KP2000 User Manual Version 1 0 EN Choose Troubleshoot from the options menu it appears Choose Advanced options from the Troubleshoot menu ...

Page 31: ...KP2000 User Manual Version 1 0 EN 31 of 33 Choose Startup Settings from the Advanced options menu Click Restart ...

Page 32: ... system will boot with the digital signature check disabled This will allow installing any unsigned USB Driver After a reboot of the system the digital signature check will be enabled again The drivers that have already been installed will remain on your system but if you want to install new unsigned drivers you will need to perform this procedure again ...

Page 33: ...PC E 1 Value 01234565 EAN 13 Value 1234567890128 EAN 8 Value 12345670 ISBT ISSN Value 9781234567897 CODE 39 Value 1234 ABCD Code Interleaved 2 of 5 Value 0123456784 CODABAR Value A12345678 B CODE128 Value A12345678B UCC ENA128 Value 0101234567890128 Code 93 Value ABC 1234 A87654612 Code 32 Value 87654612 ...