INITIAL INSTALLATION MANUAL
AF INTEGRA / AF-H INTEGRA
PAGE: 26
JUN 01/2011
External warning installation and connection (option):
Refer to Figure 42:
RC200 Wiring diagram, page 50
Connect the female 9-pin D-SUB connector to the male 9-pin D-SUB plug
of the RC200.
(4) RC300 / RC300-NVG
The RC300 RCP is designed to be installed in a standard rack of an aircraft
cockpit. As compliant with NF L 65-211 standard, no drilling is necessary
to install this RCP.The precise location of RC300 is to be determined
according to aircraft manufacturer instruction.
A male 9-pin D-SUB connector, reference AMPHENOL 17DE09PTZ or
equivalent, must be used as mating connector to connect the bundle to the
RCP connector.
Connection with DIN-12 connector or Programming dongle
Refer to Figure 43: RC300 Wiring diagram, page 51
Fabricate a 4-wire bundle (AWG 24, shielded preferred) long enough to
reach between the ELT installation location and the cockpit panel RCP
location. Slide heat-shrinkable sleeves on both sides of each wire.
On the ELT side:
- Solder the wires to the DIN-12 connector (or programming dongle) to be
connected to the ELT or to the DIN-12 male connector of RCP bundle if
a Programming Dongle ASSY is used (
Refer to Figure 17: Programming
Dongle ASSY
).
On the RCP side:
- Solder the wires to the male 9-pin D-SUB connector according to wiring
diagram.
- If an optional outside buzzer is connected:
• Mount and install the buzzer:
Refer to Section 7. Outside Buzzer
Installation, page 28
• Connect the buzzer:
Refer to Figure 43: RC300 Wiring diagram, page
51
.
Put heat-shrinkable sleeves to protect the pins.
- Connect the male 9-pin D-SUB connector to the female 9-pin D-SUB
plug of RC300.