INITIAL INSTALLATION MANUAL
AF INTEGRA / AF-H INTEGRA
PAGE: 25
JUN 01/2011
Figure 20: Installation of RC200 with mounting tray
Connection
Refer to Figure 42: RC200 Wiring diagram, page 50
RC200 is an RCP without internal buzzer. It can be connected to an
optional outside buzzer and/or to an external warning
A 3-wire bundle is required to connect RC200 to the ELT. If the optional
outside buzzer and/or external warning is installed, a 4-wire bundle is
required.
Fabricate a 3 or 4-wire bundle (AWG 24, shielded preferred) long enough
to reach between the ELT installation location and the cockpit RCP
location.
Slide heat-shrinkable sleeves on both sides of each wire.
On the ELT side:
- Solder the wires to the DIN12 connector supplied with the pack
according to wiring diagram.
- Put heat-shrinkable sleeves to protect the pins
On the RCP side:
- Solder the wires from DIN-12 connector to the female 9-pin D-SUB
connector according to wiring diagram.
- Put heat-shrinkable sleeves to protect the pins.
Outside buzzer installation and connection (option)
- Mount and install buzzer:
Refer to Section 7. Outside Buzzer
Installation, page 28
.
- Connect the outside buzzer:
Refer to Figure 42: RC200 Wiring diagram,
page 50
.
Summary of Contents for AF INTEGRA