INITIAL INSTALLATION MANUAL
AF INTEGRA / AF-H INTEGRA
PAGE: 24
JUN 01/2011
Connect RCP to ELT
Solder the DIN12 connector or Programming Dongle on the other side of
the bundle (pins K and M):
Refer to Figure 41: RC102 Wiring diagram, page 49
Stuck the "CAUTION label" on the cable bundle close to the DIN12
connector.
(3) RC200
The RC200 RCP is designed to be installed:
- either on the instrument panel with 4 screws (rivets bush recommended,
not supplied );
- or below the instrument panel with a special mounting tray (supplied).
Installation on the instrument panel
- Determine RC200 location on the instrument panel:
- Make a cutout on the instrument panel according to the Drilling mask
(
Refer to RC200 Outline Dimensions, page 39
).
- Mark the 4 holes needed for the RC200 using the drilling mask or the
RC200 as a guide.
- Drill the 4 marked holes, diameter depending on rivets bush used.
- Install the RC200 by fitting it into the cutout.
- Secure the RC200 (4 rivets bush recommended).
Note: Rivets bush are not supplied.
Installation below the instrument panel
Refer to Figure 20: Installation of RC200 with mounting tray
.
Determine RC200 location below the instrument panel (be sure the
location meets the requirements established in RTCA-DO-204).
- According to the "area to be drilled" (1) of the mounting tray (3),
determine the location of the screws or rivets (2) used to secure the
mounting tray (3) to the instrument panel (4).
- Drill 2 holes on the mounting tray and on the instrument panel, diameter
depending on screws or rivets used.
- Secure the mounting tray (3) to the instrument panel (4).
- Secure the RC200 (5) to the mounting tray (3) with the 2 screws (6)
supplied (torque 0.8 Nm).