
KM9106 Operators Manual
34
The above example will send the Time and Oxygen reading to the printout every two
minutes.
To stop the Quintox Auto printing or logging, select Auto print
OFF
above and return
to the main displays.
7.2.1 Standard Printout - Parameter Options Used:
LINE
NUMBER
PARAMETER
USED:
(MAX LINES: 40) & STATUS:
1
- - - - - - - - - - - -
PRINTOUT START
2
BLANK LINE
3
***KANE-MAY***
MANUFACTURER ID
4
**KM QUINTOX**
ANALYSER ID
5
BLANK LINE
6
DATE 02-01-97
DATE
7
TIME 18 :14:35
TIME
8
BLANK LINE
9
NATURAL GAS
FUEL SELECTED
10
BLANK LINE
11
02 % ......20.9
FLUE GAS 0
2
CONTENT
12
CO ppm .....0.0
FLUE GAS CO CONTENT
13
Prs mbar ....0.05
PRESSURE MEASUREMENT
14
EFF %.....FAULT
COMBUSTION EFF CALC
15
BLANK
LINE
16
XAIR O2>20%
FLUE GAS EXCESS AIR
17
C02 %.......0.0
FLUE GAS CO
2
CALC (CO2m% FLUE GAS
CO
2
MEASURE)
18
CO/CO2 R....0.00
CO/CO
2
RATIO
19
PI % .....0.00
POISON INDEX
20
NO ppm.....0
FLUE GAS NO CONTENT
21
NO2 .....0
FLUE GAS NO
2
CONTENT
22
NOx ppm.....0
NOX CALCULATION
23
SO2 ppm.....0.0
FLUE GAS S0
2
CONTENT
24
CxHy % ...... 0.0
HYDROCARBON READING
25
BLANK LINE
26
NETT C 0.0
NET FLUE GAS TEMP
27
FLUE C 21.0
ACTUAL FLUE GAS TEMP
28
INLT NOT
FITTED
BOILER INLET TEMP
29
AMBIENT C 16.9
AMBIENT AIR TEMP
30
- - - - - - - - - - - -
DOTTED LINE
Not all parameters are used. See the master list on the next page if more are required.