
KM9106 Operators Manual
9
4.3.2 Line Scroll Mode
Line scroll mode allows you to customise the display.
Use the
key to change the bottom line of the display. Once the correct line is
displayed press to confirm and move the line up. Select the next parameter and
repeat until all lines display the desired parameters.
Change bottom line using
NETT C
. . .
0.0
O2 %
. . .
20.9
CO ppm
. .
0000
CO2 %
. . .
0.0
to select and move
parameter up
O2 %
. . .
20.9
CO ppm
. .
0000
CO2 %
. . .
0.0
CO2 %
. . .
0.0
Select next parameter.
Repeat above until
display reads desired data
O2 %
. . .
20.9
CO ppm
. .
0000
CO2 %
. . .
0.0
CO/CO2 R
. .
0.0001