Nesis III — Installation Manual
2.4
Mounting Procedure
2.4.1
Fixation with Supplied M3 nut and Lock Washer
This is the most straightforward method of fixation. Figure 5 shows an ex-
ample.
4
5
1
2
3
Figure 5:
An example of fixation using supplied M3 nut and lock washer.
1
O
Nesis plastic bezel – made of ABS plastic.
2
O
Instrument panel plate.
3
O
M3 bolt with head colored black.
4
O
External teeth lock washer.
5
O
Standard M3 nut.
Please do not use excessive force on M3 bolt/nut to avoid damage of plastic
bezel.
This fixation principle has one disadvantage – it makes Nesis service removal
a bit difficult as nut on the back side may be difficult to access.
2.4.2
Fixation with Self-Clinching Nut
Instead of using standard nut and lock washer, a self clinching nut may be
used. They come in various forms, which depend on the instrument panel
material. Some special tools like arbor press may be required.
For instrument panels made of aluminum, a nut like shown on Figure 6 can be
used. The nut must be pressed into the panel before installing the instrument.
15
©
Kanardia
2018