Nesis III — Installation Manual
1.3
Minimal System
Before installing the instrument, you shall carefully read and understand
this manual and any other supplementing manual.
The manual is not a substitute for an approved aircraft specific main-
tenance manual, installation or design drawing. Attempting to install
Nesis and corresponding equipment by reference to this manual only
(without planning or designing an installation specific to aircraft) may
compromise the safety and is not recommended.
1.3
Minimal System
Nesis minimal system consists of two components: Nesis III display and
DAQU (engine management box). They are sold together as a kit.
This manual starts with the installation instructions for the minimal system
and then adds separate sections for optional components.
Some components have their own installation manuals.
2
Display Installation
This section covers the installation of the Nesis display.
2.1
Placement Consideration
There are several consideration which affect the display position on the in-
strument panel.
The display must be in direct view field of the pilot without any ob-
structions.
The display supports landscape orientation only. Portrait orientation is
not possible.
The display has a modest power consumption. It is cooled trough top
and bottom openings in the housing. Please make sure that cooling air
will be able to circulate trough the housing openings.
Avoid to place the display next to the heater vents or into any kind of
direct stream of hot air.
10
©
Kanardia
2018