9.5
Auxiliary supply [97A-98A]
MULTICAL
®
801 comprises a built-in auxiliary supply on terminals 97A-98A. The auxiliary supply is based on an
unstabilized power supply. This means that the output voltage varies depending on load.
The output current must not exceed 50 mA and the nominal output current is 35 mA.
The auxiliary supply is suitable for e.g. supplying a Lon-module or a passive flow meter output.
The built in auxiliary supply is available on terminals 97A-98A.
The voltage on terminals 97A-98A varies according to load.