MULTICAL® 801
54
Kamstrup A/S · Technical Description · 5512-571_R1_GB_11_2016
6.11
Tariff functions
MULTICAL
801 has 2 extra registers TA2 and TA3, which can accumulate heat energy (EE=20 accumulates volume)
parallel with the main register, based on a programmed tariff condition. Irrespective of the selected tariff form, the
tariff registers are named TA2 and TA3 in the display. The tariff function can only be used for heat energy (E1).
The main register is always accumulated as it is considered legal billing register, no matter the selected tariff
function. Tariff conditions TL2 and TL3 are monitored with each integration. If the tariff conditions are fulfilled,
consumed heat energy is accumulated in either TA2 or TA3 parallel with the main register.
2 tariff conditions, TL2 and TL3, which are always used in the same tariff type, are connected to each tariff
function. However, it is not possible to “mix” two tariff types.
Example: EE=11 (Power tariff)
TA2 shows energy consumed…
…above power limit TL2 (but below TL3)
Mai
n r
eg
ist
er
TA
2
TA
3
0
10
20
30
40
50
60
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Po
w
e
r
(k
W
)
Integrations
Power tariff