MULTICAL® 801
72
Kamstrup A/S · Technical Description · 5512-571_R1_GB_11_2016
7.2.2
Flow sensor coding
Installing the sensor it is important that both flow sensor and MULTICAL
are correctly programmed. The below-
mentioned table lists the most frequently used flow sensor codes:
Number of decimals in display
CCC
No.
Pre-
counter
Flow
factor
MWh
Gcal
GJ
m³
[
ton
]
m³/h
MW
l/imp
Imp./l
Qp range
[
m³/h
]
Qs
[
m³/h
]
Type
Flow
sensor
201
100
235926
2
1
1
1
2
1
1
10…100
75
FUS380
DN50-65
N
202
40
589815
2
1
1
1
2
2.5
0.4
40…200
240
FUS380
DN80-100
N
203
400
589815
1
0
0
1
2
2.5
0.4
100…400
500
FUS380
DN125
N
204
100
235926
1
0
0
0
1
10
0.1
150…1200
1600
FUS380
DN150-250
N
205
20
1179630
1
0
0
0
1
50
0.02
500…3000
3600
FUS380
DN300-400
N
206
100
2359260
0
x10
x10
0
1
100
0.01
1400…18000
36000
FUS380
DN500-1200
N
Table 3