The module is specially suited for installation together with a 230/24 V safety transformer, e.g. type 66-99-403,
which can be installed in the meter panel before the safety relay. When the transformer is used the power
consumption of the total meter incl. the 230/24 V transformer will be lower than 1.7 W .
10.4
Change of supply unit
The supply unit for MULTICAL
®
61 can be changed from mains supply to battery or visa versa as the needs of the
utility change. Thus, it can be an advantage to change mains supplied meters to battery supplied meters in
buildings under construction where the mains supply can be unstable or periodically missing.
The change from battery to mains supply or visa versa does not require reprogramming as MULTICAL
®
61 does not
include an information code for worn out battery.
However, mains supply must not be changed to battery if MULTICAL
®
61 is fitted with one of the following base
modules:
MULTICAL
®
61 Type 67-
Z
0
Base module
RadioRouter + pulse inputs
21
Prog. data RTC + 4…20 mA pulse inputs
22
0/4…20 mA outputs
23
LonWorks, FTT-10A + pulse inputs
24
See paragraph 11.1.3 concerning supply options for top and base modules