TECHNICAL DESCRIPTION
MULTICAL
®
61
5512-622 GB/01.2011/Rev. E1
11
3.2
Type number, flow sensor
ULTRAFLOW
®
24
Nom.
flow
Q
3
Max.
flow
Q
4
Min.
flow
Q
1
Min.
cut off
Pressure
loss
∆
p @ Q
3
Connection
on meter
Length
Anti-
pollution
check
valve
1)
Strainer
1)
Type number
[
m
3
/h
]
[
m
3
/h
]
[
l/h]
[
l/h]
[
bar
]
[
mm
]
65-2
-CDAA
-XXX
1.6
2.0
16
3
0.25
G¾B (R½)
110
-
-
65-2 -CDAC
2)
-XXX
1.6
2.0
16
3
0.25
G¾B (R½)
165
OK
OK
65-2
-CDA1
-XXX
1.6
2.0
16
3
0.25
G1B (R3/4)
110
-
-
65-2
-CDAF
-XXX
1.6
2.0
16
3
0.25
G1B (R3/4)
190
OK
OK
65-2
-CEAF
-XXX
2.5
3.1
25
6
0.04
G1B (R3/4)
190
OK
OK
65-2
-CGAG
-XXX
4.0
5.0
40
7
0.09
G5/4B (R1)
260
OK
OK
65-2
-CHAG
-XXX
6.3
7.9
63
12
0.22
G5/4B (R1)
260
OK
OK
65-2
-CJAJ
-XXX
10
12.5
100
20
0.06
G2B (R1½)
300
OK
OK
65-2
-CKCE
-XXX
16
20
160
30
0.16
DN 50
270
-
-
65-2
-CLCG
-XXX
25
31.3
250
50
0.06
DN 65
300
-
-
65-2
-CMCH
-XXX
40
50
400
80
0.05
DN 80
300
-
-
Table 1
1) Anti-pollution check valve and strainer are only valid options for cold water meter.
2) MULTICAL
®
61 with flow sensor type 65-2-CDAC (G¾B x 165) is only available as cold water meter.
The type number of the flow sensor cannot be changed after factory programming
The delivery code can also be used for:
•
Language and approvals on type label
•
Marking of PN class
Customer labels (2001-XXX) are integrated in the front label.