8.4.1
Changing the installation position
The setup of the meter's installation position can be changed from inlet meter to outlet meter (and vice versa):
Setup loop
When the meter is in operation Setup loop can be
selected by breaking the seal and using the short-
circuit pen to make a brief short-circuit, which
makes the reading shown to the left appear.
Do not forget to seal with a void label.
Installation position, reading 3-06
Subsequently reading 3-06 is found by means of the
button below the display.
Inlet
If the meter is set to be a inlet meter, the text "inlet"
is displayed. In order to change the setting, press
the button for two seconds. ”Setup” is briefly
displayed and then ”Inlet” flashes. Press the button
once and "Outlet" is displayed. If you want to save
the setting, press the button for two seconds until
”OK” appears in the display.
Outlet
If the meter is set to be a outlet meter, the text
"Outlet" is displayed. In order to change the setting,
press the button for two seconds. ”Setup” is briefly
displayed and then ”Outlet” flashes. Press the
button once and "Inlet" is displayed. If you want to
save the setting, press the button for two seconds
until ”OK” appears in the display.