MULTICAL® 302
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
47
7.8.2
Info logger
Every time the information code has remained changed for minimum one hour, date and info code are logged. Thus, it
is possible to data read the latest 50 changes of the information code as well as the date the change was made.
Register type
Description
Date (YY.MM.DD)
Logging time: year, month and day
Info
Information code on above date
E1
Heat energy
E3
Cooling energy
Clock (hh.mm.ss)
Time
If the info logger is read from the display, the latest 36 changes including dates can be read too. All of the 50 changes
can be read by means of the PC program LogView HCW.
7.8.3
Configuration logger
Every time configuration is changed, date, energy and the new config. are logged. Thus, it is possible to data read the
latest 25 configuration changes as well as the date the change was made. The meter only permits 25 config. changes,
unless the legal seal is broken.
Register type
Description
Date (YY.MM.DD)
Year, month and day of config. change
E1 and E3
Counter values just before reconfiguration
Config. ABDDDEFGHHMMM
The new config. number