MULTICAL® 302
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
17
3.2.1
Integration time
Depending on selected type number MULTICAL
®
302 is from the factory configured for integration (energy calculation)
every 32 seconds or every 8 seconds.
Supply
6 year battery, Normal Response meter
1
12 year battery, Normal Response meter
2
6 year battery, Fast Response meter
3
Among other things the meter's current consumption depends on the integration frequency of the meter. A Fast
Response meter integrates every 8 seconds and uses almost twice as much current as a Normal Response meter. This
means that the battery life is halved.
Normal Response cannot be changed to Fast Response and vice versa after delivery.
3.2.2
Configuration during setup of country code
The last two characters of the type number are called the country code. The code is used for setting up language of text
on label e.g. class 2 or 3, dynamic range, pressure stage PN16 or PN25, and indicates approval and verification marks.
Please contact Kamstrup for further details on available country codes. Currently available country codes appear from
internal document 5514-863 on Kamstrup’s Intranet.
3.2.3
Accessories
3026-655.A Wall fitting (LEXAN 3412R black)
6561-346
Holder for optical reading head
3130-362
Blind plug for temperature sensor in flow part (Copper alloy brass, CW614N)
6556-491
R½ x M10 nipple (Copper alloy brass, CW614N)
6556-492
R¾ x M10 nipple (Copper alloy brass, CW614N)
5920-257
G½ ball valve with M10x1 sensor socket
5920-271
G¾ ball valve with M10x1 sensor socket
6557-302
G½ sensor pocket 35 mm (Copper alloy brass, CW614N)
6699-099
Infra-red optical reading head w/USB plug
6699-102
Infra-red optical reading head RS232 w/D-sub 9F
6699-304
Infra-red optical reading head for NOWA
6699-016
Kamstrup NOWA KAS software
6699-724
METERTOOL HCW
6699-725
LogView HCW
Note
: Ball valves with M10x1 socket (type: 6556-474, -475 and -476) are not suitable for sensors with O-ring seal
as they are intended for flat gaskets.