MULTICAL® 302
40
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
7.5
Max. flow and max. power
MULTICAL
302 registers maximum flow values and maximum power values on a yearly as well as a monthly basis. The
registration can be read via data communication or via the display in ”TECH mode”.
Max. registration includes the following flow and power values with indication of date:
Type of registration:
Max. this year (since latest target date MM.DD)
Max. yearly data, up to latest 15 years
Max. this month (since latest target date DD)
Max. monthly data, up to latest 24 months
All max. values are calculated as the highest average of a number of current flow or power measurements. The average
period used for all calculations can be selected in the interval 1...1440 min. in one minute leaps. (1,440 min. = 24
hours).
Average period and target date must be stated in the order or reconfigured by means of METERTOOL HCW. Unless
otherwise stated in the order, average period will be set at 60 min. and the target date applying to the selected delivery
code will be used, normally the first day of each month or first January every year.
At the end of a year or a month max. values are saved in the data logger, and the current max. registers are “reset”
according to selected target date and the meter’s internal clock and calendar.
Date of this month’s max. power
Lines above and below the month indication
show that monthly data are displayed.
Value of this month’s max. power
Example of max. power on a monthly basis
Date of this year’s max. flow
Lines above and below the year indication
show that yearly data are displayed.
Value of this year’s max. flow
Example of max. flow on a yearly basis