MULTICAL® 302
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
15
3
Type overview
MULTICAL
®
302 can be ordered in various combinations as required by the customer. First select the required
hardware from the type overview. Then select ”Config” and ”Data” to suit the application in question.
The meter is configured and ready for use from the factory. It can, however, be reconfigured before installation (see
paragraph 8.4 Setup loop for further information).
3.1
Type and configuration overview
Type number
302-T-xx-x-xx-xx-xxx
Type number and serial number (factory set
unique serial no.) are written on the meter
and cannot be changed after production.
CONFIG >AB<
Inlet/outlet - Measuring unit - Resolution
- Can be changed via the pushbutton while
the meter is still in transport state.
- Later, the seal ”I (SETUP)” must be broken
and the switch activated in order to change
the configuration.
CONFIG >DDD<
Display
Change only possible via METERTOOL
provided that the seal ”I (SETUP)” is broken
and the switch activated.
CONFIG >EFGHHMMM<
Other configurations (see paragraph 3.6)
Change only possible via METERTOOL
provided that the seal ”I (SETUP)” is broken
and the switch activated.
CONFIG ”ABDDD-EFGHHMMM” is not written
on the meter, it can be read from the
display.
DATA
-
Can be changed via the pushbutton while
the meter is still in transport state.
- Later, data can only be changed via
METERTOOL provided that the seal ”I
(SETUP)” is broken and the switch
activated.
- Customer No.
- Target date
- Average peak time (Max. flow and power)
-
θ
hc
(only active for meter type 6)
- Date/time
- M-Bus primary address