MAXICAL
®
III
5511-229 GB/98.06/Rev. B1
52
where Q
GJ
and Q
MWh
can be seen in the following Quick table:
CCC-code (read chapter 6.1 - 6.3)
Q
GJ
Q
MWh
Decimals with
[m
3
] display
000, 001, 002, 108, 109, 110, 111, 112, 115,
116, 117, 118, 119, 121, 122, 123, 124, 125,
126, 132, 133, 134, 136, 139, 156, 164, 165,
165, 300, 310
2.388.900
8.600.000
x 0,01 m
3
003
955.200
3.440.000
x 0,1 m
3
004, 006, 113, 114, 120, 127, 128, 129, 130,
131, 135, 137, 140, 141, 142, 143, 151, 152,
153, 157, 168, 301, 311
238.890
860.000
x 0,1 m
3
005, 007
95.520
344.000
x 1 m
3
008, 144, 145, 146, 147, 148, 149,
158, 169, 170, 302, 312
23.889
86.000
x 1 m
3
171, 172, 303, 313
2.388,9
8.600
x 10 m
3
Example of true Quick-figure calculation:
*
MAXICAL
®
III
*
Programmed for Qn 1.5 m
3
/h flow meter (CCC=119)
*
Fitted in flow pipe
*
10,000 volume pulses, corresponding to 0.1 m
3
registered
*
The temperature is simulated to: t
F
= 49.00°C and
t
R
= 40.00°C.
E
MJ
= m
3
x
D
t x k
STUCK
= 0.1 x 9 x 4.1316 = 3.71844 [MJ]
EMJ
x
QGJ 3.71844
x
2,388.900
1000
1000
Quick =
=
= 8883