IASMANUAL 0821
KAM CONTROLS, INC.
3
I N T R O D U C T I O N C O N T I N U E D
SAMPLER SEQUENCE
FIG. 1-4
THEORY OF OPERATION
Operating similarly to a downhole pump, the KAM
®
IAS™ Isokinetic Automatic Sampler extracts a known volume of
pipeline fluids for collection in a KAM
®
SR™ Sample Receiver. Sampling is pneumatically or hydraulically driven, and
the time interval can be flow-based or time-based. All KAM sampling components comply with API MPMS Chapter
8.2, ASTM D4177, and ISO 3171 standards requirements.