- 6 -
2.
Purpose
Solid fuel water heating boiler
Kalvis 2-30U
,
Kalvis 2-40U
(hereinafter referred
to as boiler) is designed for heating of various premises where central heating
system is installed with natural or forced circulation and closed or open expansion
system. The boiler operates most efficiently under nominal taken thermal power, if
operating with lower power, accumulation capacity is recommended to use.
3.
Main Technical Specifications
Boiler model
Kalvis-2-30U
Kalvis-2-40U
Nominal power (Q
N
), kW *
30
40
Minimum power (Q
min
), kW *
8
15
Heated area, m
2
,
when building partition thermal resistance is ~ 2,5 m
2
·K/W
220 ... 380
300 ... 480
Fuel consumed *
firewood ****
Size of firewood L x Ø, up to, cm
35 x 15
45 x 15
Position of firewood in hearth
across or along
across
Loading hole sizes, mm:
from top
288 x 492
288 x 592
from bottom
230 x 292
230 x 292
Hearth volume, dm
3
(l)
160
200
Fuel * combustion time (Q
N
), hrs.
4 ... 5
Approx q-ty of consumed firewood per season, Q
N
/ Q
min
, m³ *
18 ... 28
25 ... 35
Efficiency rate during operation at nominal power, no less than, %
82
Boiler class under LST EN 303-5
2
Boiler water capacity, l
102
116
Min volume of accumulation capacity, l *
800
960
Water pressure in boiler no more than, MPa (kgf/cm
2
)
0,15 (1,5)
Max permissible water temperature, ºC
95
Min return water temperature during operation, ºC
57
Hydraulic resistance, mbar
8
8,3
Operation environment temperature, ºC
3 ... 60
Temperature regulator adjustment range, ºC
65 ... 90
Parameters of cold water used for excess
heat dissipation: ** (***)
pressure, bar
≥
2,0 **
temperature, ºC
≤
15 **
Min chimney draught, Pa
26
35
Adjustable exhauster node type ***
DM-01
Adjustable cooling coil type ***
AAG9
Exhausted flue temperature, up to (Q
N
/ Q
min
):, ºC
200 / 90
200 / 90
Exhausted gas volume at Q
N
, kg/s (m
3
/val)
0,025 (113)
0,035 (158)
Exhausted gas volume at Q
min
, kg/s (m
3
/val)
0,013 (59)
0,016 (72)
Connection flange sizes:
to exhauster (K),
mm
to system (M), G
for output (N), G
Ø178
G2-B
G½-B
Sizes, no more than
(Overall / at transportation on pallet)
height, mm
width, mm
length, mm
1540 / 1700
715 / 800
1260 / 1300
1540 / 1700
815 / 900
1260 / 1300
Mass, no more than (net/gross), kg
364 / 385
473 / 494
*
Firing with 18-20 % damp birch firewood.
It is not recommended to fire with firewood damper than 30%.
** For boilers with emergency cooling system installed.
*** Available for installation having purchased separately.
**** As spare fuel, coal, lump wood waste, chip or peat briquettes can be used.
- 27 -
KALVIS - 2-30U, -2-40U 2012.02.06
14.
Product warranty and guarantee service conditions
Manufacturer guarantees that product is in line with technical
documentation requirements.
•
If you correctly install and operate the boiler in accordance with these
instructions, the following guarantee service period will be applied
calculated from the purchase date:
- for boiler case
- 24 months.
- for completing parts
- 12 months.
- for wearing parts
- 6 months.
•
Please take care for the installation works performing person or firm
filled the installation report.
•
Manufacturer obliges to eliminate failures occurring due to its fault
during the mentioned period for free.
•
Manufacturer takes no obligation for boiler operation and related
consequences, grants no warrant if the boiler is inadequately selected,
poorly installed (see chapter 6) or operated (see chapter 7) and this is
found out during the visit at user. In this case user shall pay for
technicians’ arrival and repairs!
•
No rarely than once a year perform revision of the boiler and its control
elements with the help of adequately qualify specialists.
•
Keep purchase receipt or invoice throughout the warrant period.
•
For warrant repairs apply to this service providing company, specified by
seller.
•
In the case of boiler failure, apply to the specified service, upon its
arrival fill the application form shown on the last page.
•
We ask user to take care for after warrant repairs service employee made
relevant record in this certificate “Notes about warrant and non-warrant
repairs” and filled warrant repairs report
I familiarized with warrant repairs conditions. I am informed that in the
case boiler is installed and operated without observing the requirements
given in this manual otherwise I loose the right for warrant repairs.
Buyer:
(name, surname, signature)
Example