background image

INSTALLATION INSTRUCTIONS

  In-Wall Tank and Carriage  

1206758-2-C

Questions? Problems? For additional assistance, please contact KALLISTA’s Customer

Service Department at 1-888-4KALLISTA (1-888-452-5547) or kallista.com.

8 of 12

6.  SECURE THE TOP OF THE CARRIAGE

2x4

Screws

Lag Bolt

1-5/8" 
(41 mm)

Inlet

6" (152 mm)

Ø 2" 
(51 mm)

 

Drill pilot holes at the lag bolt locations.

 

Install two 6” (152 mm) long support 2x4’s, located at the top of the carriage, aligned with the mounting 
holes, 1-5/8” (41 mm) in from the front edge of the studs.

 

Secure the carriage to the support studs using 2” (51 mm) long (minimum) lag bolts (not supplied), one on 
each side.

 

At the location of the inlet, drill a 2” (51 mm) hole.

Summary of Contents for P70362

Page 1: ...IONS In Wall Tank and Carriage 1206758 2 C Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4KALLISTA 1 888 452 5547 or kallista com 1 of 12...

Page 2: ...an interior wall If installed on an exterior wall provide adequate insulation to prevent the possibility of freezing NOTE This device is not intended to be used as a retrofit device for 1 28 gpf 4 8 l...

Page 3: ...E Refer to the specification sheet for more details and dimensions for roughing in NOTE The waste outlet pipe may need to be relocated for this installation NOTE The recommended install height from th...

Page 4: ...ARE THE CARRIAGE Nut Leg Hex Wrench Back View Front View NOTE Raise the carriage for ease of installation It will be lowered again in a later step Position the carriage face down on the floor Loosen t...

Page 5: ...ently turn the upper screw labeled Open counterclockwise while applying slight downward pressure on the support strap until the strap comes free of the locking mechanism Move the end of the elbow into...

Page 6: ...place so it will not fall Align the carriage flush with the front edge of the studs The front of the carriage should be flush with the front edge of the studs or set back slightly for finished wall i...

Page 7: ...8 391 mm when the finished floor is even with the bottom of the carriage legs The maximum rim height is 26 660 mm when the legs are fully raised The carriage can be adjusted up to 12 305 mm with 6 152...

Page 8: ...TOP OF THE CARRIAGE 2x4 Screws Lag Bolt 1 5 8 41 mm Inlet 6 152 mm 2 51 mm Drill pilot holes at the lag bolt locations Install two 6 152 mm long support 2x4 s located at the top of the carriage align...

Page 9: ...For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4KALLISTA 1 888 452 5547 or kallista com 9 of 12 7 INSTALL THE WATER SUPPLY Install the water supply pipes fol...

Page 10: ...or kallista com 10 of 12 8 INSTALL THE PLASTER GUARDS Screws Flush Shield Inlet Hole Outlet Hole Plaster Guard Insert a plaster guard into the inlet hole in the carriage Install a plaster guard into...

Page 11: ...mm 8 203 mm 10 254 mm 2 52 mm Centerline of Outlet Centerline of Cutout Install a minimum 24 610 mm by 24 610 mm piece of cement board with a 10 1 2 267 mm by 10 254 mm hole installed directly behind...

Page 12: ...amaged B Replace the gasket or flush valve as necessary C Flush valve is sticking open C Check the flush valve and actuating mechanisms for free movement Push button actuators should raise levers then...

Reviews: