5.
Adjust the Valve – Right Handle
NOTICE: Risk of property damage.
The water supply must be shut off before
performing these steps.
Shut off the water supply.
Remove the plaster guard/retaining ring tool.
Position a bucket at the spout outlet, then open the valve handle to relieve water
pressure. Leave the handle open.
Loosen the threaded retaining ring using the plaster guard/retaining ring tool
until the valve body disengages from the mixer valve.
NOTICE: Risk of property damage.
At the maximum valve body extension, a detent
will be encountered. To avoid leakage, do not extend the valve beyond this detent. If
the valve body needs to be extended further, installation of the deep rough-in valve
body kit (1107027) is required. If the valve needs to be recessed further, installation of
the shallow rough-in valve body kit (1107026) is required.
Using a straight edge, adjust and hold the valve body flush with the finished wall.
NOTE:
A screwdriver inserted through the holes in the plaster guard/retaining ring
tool can serve as a handle.
With the valve body flush with the finished wall, retighten the retaining ring with
the plaster guard/retaining ring tool.
Close the valve handle.
Turn on the water supply and check that the valve is functioning properly.
Threaded Retaining Ring
Anneau de retenue fileté
Anillo de retención roscado
Plaster Guard/Retaining
Ring Tool
Renfort en plâtre/Outil d'anneau
de retenue
Herramienta para protector de
yeso/anillo de retención
1156628-2-A
12
Kallista