X K 3 1 9 0 - D S 1
5
First frame
:
signal bit is 0
X
:
D0
、
D1
、
D2 – are decimal point ( 0
~
4 )
Y
:
D3 — weight symbol( 1
-
negative
、
0
-
positive )
D4 — spare use
G 18
~
G16
:
weight data
Second frame
:
signal bit is0
G15
~
G8
:
are weight data
Third frame
:
signal bit is 1
G7
~
G0
:
weight data
G0
~
G18
:
from low to high, 19 binary code composed of weight(net weighit)
5. connect to serial communication interface
▲
!
please connect the communication wire to the computer correctly. Damage might be caused
to indicator interface ,computer interface or indicator, computer and relevant devices if they are
connected incorrectly.
▲
!
only the person who has the ability of program or relevant computer skill are entitled
to operate the communication with computer, it is necessary to have a professional
person to instruct. Unprofessional person please do not operate to avoid any mistakes.
▲
! communication interface is 15 pin RS232 connector( same with scoreboard interface),
the definition of pin6,7,8(RS232) or pin 1,2,3,4(RS232) are indicated in the following
2-7
(
RS422 optional
)
RS232C communication signal
+TX -TX +R -R RXD TXD signal position
1 2
3
4 5
6
7
8
9 10 11 12 13
14 15
+OUT -OUT
Scoreboard signal output TX
(
scoreboard RS232output
)
(2-7) communication interface definition
1.
serial communication instruction
:
serial data frame is :n,8,1: 8 data bit, 1 stop bit, no check bit;XK3190-DS1 serial
communication has continuous communication method and command communication method,
serial method has 3 types; through TF parameter (please refer to the chapter 3 for the detail).
Here we just instruct 2 situations when the TF=0,1
(1). Continuous method(TF=0)
:
The transmission data is the displayed data of the indicator(gross weight). Each data frame
are composed of 12 group data.
The format is as following 2-1
: