3. Mounting and installation
16
3.5
Supply of convection air
The Heat Pure is surrounded by a
convection casing, that warms up the
room in a constantly pleasant and
efficient manner.
For this system to operate to its
maximum effect, a convection set is
required.
This optional convection set consists
of:
Heat Pure 45 and 60
•
4 flexible aluminium hoses Ø150 mm 1.25 m: 2 hoses of 2.5 m which
must be divided in half, in order to get a total of 4 hoses.
•
8 clamping strips.
•
4 gratings: outer dimensions 20 x 20 cm, recess dimension 16.5 x
16.5 cm, with connection collar Ø150 mm.
•
Mantel iron; this must be sawn to the correct size.
•
Roll of felt to create an expansion joint between the metal of the
mantel iron and the surround.
This convection set is ordered separately to the Heat Pure. Instead of a
grating, openings (for example recessed plinths) can be used. Do not
reduce the convection openings.
Place all of the gratings / openings, both upper and lower, to facilitate
the natural circulation. The gratings / openings should be situated in the
same pressure area (the same room) as the Heat Pure.
Heat Pure 70, 71, 85, 100, 105, 110 and 120
•
8 flexible aluminium hoses Ø150 mm 4x 1.25 m long and 4x 0.62 m.
2 hoses of 2.5 m which must be divided in half, in order to get a total
of 4 hoses and 1 hose of 2.5 m which must be divided into 4.
•
16 clamping strips.
•
4 gratings: outer dimensions 35 x 20 cm, recess dimension 33 x 16.5
cm, with 2 connection collars Ø150 mm each.
•
Mantel iron; this must be sawn to the correct size.