![Kaise SK-8402 Instruction Manual Download Page 42](http://html.mh-extra.com/html/kaise/sk-8402/sk-8402_instruction-manual_649657042.webp)
SK-8402
取扱説明書(英文)
_P40
40
TROUBLE SHOOTING
If there are any failure with this instrument, check the following trouble shoots before asking
repair service. Ask KAISE AUTHORIZED SERVICE AGENCY through your local dealer when there
are any questions or troubles with this instrument.
●
Batteries are exhausted.
→
Replace the batteries.
●
Batteries are installed in the wrong polarity.
→
Install the batteries in the correct polarity.
●
Pressing time of the POWER Key is too short or not enough.
→
Press POWER Key for 1 second or more.
Symptoms
Possible Causes and Necessary Treatments
Cannot turn on
the instrument
●
The temperature of the O2 sensor is cooler than the certain temperature.
→
Warm up the O2 sensor keeping constant engine speed at approx.
2,500rpm for 3 or 4 minutes. Keep the engine speed at approx. 2,500rpm
during the normal test.
Displayed value
is unstable
●
Test lead or check harness are broken.
→
Inspect whether they are disconnected. (see page 18 to 20)
●
O2 sensor or the other parts are broken.
→
Make the same test with the other cars and check if the display still have
the failure.
LCD does not display
the measurement value