PREPARATION FOR USE
⑥
Test lead wires have good continuity if "OL" blinks
on LCD. Otherwise, they should be disconnected.
This concludes the test lead inspection.
●
Inspection for Check Harness
①
Connect red and black L-shaped plugs of the test
lead to red (
+
) and black (
−
) input terminals.
②
Connect red and black check harness connecting
plugs to the red and black straight plugs respectively.
⑤
Short-circuit red and black male connecting
terminals and press TEST Key for 1 second or less
to output RICH signal.
③
Press POWER Key for 1 second or more to turn on
the instrument. It enters stand-by mode for cable
connection check.
④
Press SEL Key for 1 second or more to enter
simulation test mode for zirconia O2 sensor.
lights up on LCD.
S
RICH
Z
S
APO
RICH
Z
S
APO
Red test lead straight plug
Red check harness
connecting plug
Black test lead straight plug
Black check harness
connecting plug
Press TEST Key for 1 second or less with contacting
the tips of red and black male connecting terminals.
O
2
SENSOR CHECKER
SK-8402
TEST
SEL