![Kaise SK-8402 Instruction Manual Download Page 35](http://html.mh-extra.com/html/kaise/sk-8402/sk-8402_instruction-manual_649657035.webp)
SK-8402
取扱説明書(英文)
_P33
33
NORMAL TEST
⑤
If the O2 sensor to be measured has only 2 or 4
cables, attach black test pin to black straight plug
instead of alligator clip, and insert it to the space of
sensor earthing cable after confirming the sensor
signal by inserting red test pin to the space of
sensor signal cable (see "Confirmation of O2
Sensor Cables" and "Colors of O2 Sensor Cables"
in page 17). Start the test after confirming the
signals.
●
Maintenance of connecting coupler
Measurement by using the Test Pin might
weaken the waterproof property of the
connectors of O2 sensor and ECU. Wrap
heat-resistance/waterproof tape around
them after taking the measurement.
Red test pin
Black test pin
Sensor signal cable
Sensor earthing cable