Characteristic
Value
PTC testing current [A]
(according to EN 50342)
850
Tab. 29 Batteries
Further information Depending on machine equipment, a higher capacity battery may be required. See chapter 2.7.1 for
low temperature equipment.
2.7 Options
2.7.1 Option ba
Low temperature equipment
2.7.1.1 Ambient conditions
Positioning
Limit value
Maximum altitude AMSL* [m]
1000
Minimum ambient temperature [°C]
−25
Maximum ambient temperature [°C]
+50
* Higher altitudes are permissible only after consultation with the manufacturer.
Tab. 30 Ambient conditions
2.7.1.2 Batteries
Feature
Value
Voltage [V]
24 (2 x 12)
Capacity [Ah]
2 x 135
PTC testing current [A]
(according to EN 50342)
1000
Tab. 31 Batteries
2.7.1.3 Option bb
Coolant pre-heating
Coolant pre-heater
Value
Voltage [V]
240
Power [W]
1000
Rated current [A]
6.0
Tab. 32 Coolant pre-heater
2
Technical Specification
2.7
Options
12
Service Manual Screw Compressor
M135 SIGMA CONTROL MOBIL
No.: 9_6975 00 E