Frozen moisture can damage components, valve diaphragms and gaskets.
Advice can be obtained from KAESER on storage and commissioning.
CAUTION
Moisture and frost can damage the machine.
➤ Prevent ingress of moisture and formation of condensation.
➤ Maintain a storage temperature of >0 °C.
➤ Store the machine in a dry place, free from frost if possible.
12.4 Disposal
When disposing of a machine, drain out all liquids and remove old filters.
Precondition The machine is decommissioned.
1. Completely drain the fuel from the machine.
2. Completely drain the cooling oil and engine oil from the machine.
3. Remove used filters and the oil separator cartridge.
4. Drain the coolant from water-cooled engines and systems.
5. Hand the machine over to an authorized disposal expert.
➤ Parts contaminated with cooling oil or engine oil must be disposed of in accordance with
local environment protection regulations.
12 Decommissioning, Storage and Transport
12.4 Disposal
No.: 9_6975 00 E
Service Manual Screw Compressor
M135 SIGMA CONTROL MOBIL
165