5 Installation and Operating Conditions
5.1 Safety
➤ Strictly forbid fire, open flame and smoking.
➤ If welding is carried out on or near the machine, take adequate measures to prevent sparks or
heat from igniting oil vapors or parts of the machine.
➤ The machine is not explosion-proof:
Do not operate in areas in which specific requirements with regard to explosion protection are in
force.
For instance, the requirements of ATEX directive 94/9/EC "Equipment and Protective Systems
intended for use in Potentially Explosive Atmospheres".
➤ Ensure that required ambient conditions are maintained with regard to:
■ ambient temperature and humidity,
■ clean inlet air with no damaging contaminants,
■ inlet air free of explosive or chemically unstable gases or vapors,
■ inlet air free of acid/alkaline forming substances, particularly ammonia, chlorine or hydrogen
sulfide.
➤ Keep suitable fire extinguishing agents ready for use.
5.2 Installation Conditions
5.2.1 Place of installation and distances
The machine is intended for installation in an appropriate machine room. Information on distances
from walls and ventilation is given below.
The distances quoted are recommended distances and ensure unhindered access to all ma‐
chine parts.
➤ Please consult KAESER if they cannot be adhered to.
Precondition The floor must be level, firm and capable of bearing the weight of the machine.
5
Installation and Operating Conditions
5.1
Safety
32
Service Manual Screw Compressor
ASD T Tri-Voltage
9_5721 06 USE
Summary of Contents for ASD 25
Page 1: ...Service Manual Screw Compressor ASD T Tri Voltage 9_5721 06 USE...
Page 2: ...Original instructions KKW SASD 1 00 en 01 SBA SCHRAUBEN TRI VOLTAGE T SC...
Page 8: ...List of Illustrations vi Service Manual Screw Compressor ASD T Tri Voltage 9_5721 06 USE...
Page 10: ...List of Tables viii Service Manual Screw Compressor ASD T Tri Voltage 9_5721 06 USE...