![KAESER ASD 25 Service Manual Download Page 22](http://html1.mh-extra.com/html/kaeser/asd-25/asd-25_service-manual_649423022.webp)
ASD 25
ASD 30
ASD 40S
ASD 40
Maximum working pres‐
sure [psig]
(heat transfer medium)
145
145
145
145
Max. permissible dis‐
charge temp. [ °F]
212
212
212
212
Pressure drop [psi]
<1.5
<1.5
<1.5
<1.5
Unsuitable heat transfer
media
Seawater
Consult KAESER before using another type of heat transfer medium.
Tab. 23 Heat exchanger specification (option W2/W3)
Heat capacity
Maximum heat capacity
available
ASD 25
ASD 30
ASD 40S
ASD 40
[kW]
16.4
19.3
23.9
27.6
[MJ/h]
59
69
86
99
[kcal/h]
14101
16578
20567
23732
Tab. 24 Heat capacity (option W2/W3)
Flow rate for heating from 110 °F to 160 °F (ΔT=25K)
ASD 25
ASD 30
ASD 40S
ASD 40
Flow rate [gpm]
2.51
2.95
3.70
4.62
Tab. 25 Flow rate (option W2)
Flow rate for heating from 60 °F to 160 °F (ΔT=55K)
ASD 25
ASD 30
ASD 40S
ASD 40
Flow rate [gpm]
1.10
1.32
1.63
1.89
Tab. 26 Flow rate (option W3)
2.16 Refrigeration dryer
Model
ASD 25
ASD 30
ASD 40S
ASD 40
Model*
*Transfer data from dryer
nameplate to the table.
Tab. 27 Refrigeration dryer: model
2
Technical Data
2.16 Refrigeration dryer
12
Service Manual Screw Compressor
ASD T Tri-Voltage
9_5721 06 USE
Option W2
Option W3
Summary of Contents for ASD 25
Page 1: ...Service Manual Screw Compressor ASD T Tri Voltage 9_5721 06 USE...
Page 2: ...Original instructions KKW SASD 1 00 en 01 SBA SCHRAUBEN TRI VOLTAGE T SC...
Page 8: ...List of Illustrations vi Service Manual Screw Compressor ASD T Tri Voltage 9_5721 06 USE...
Page 10: ...List of Tables viii Service Manual Screw Compressor ASD T Tri Voltage 9_5721 06 USE...