![KAESER ASD 25 Service Manual Download Page 14](http://html1.mh-extra.com/html/kaeser/asd-25/asd-25_service-manual_649423014.webp)
Option
Option code
Exists?
Heat recovery ΔT=55 K
W3
Tab. 3 Options
2.3 Weight
The weight given is the maximum. The actual weight of individual machine is dependent on equipment
fitted.
ASD 25
ASD 30
ASD 40S
ASD 40
Weight [lb]
3640
4040
4080
4320
Tab. 4 Machine weight
2.4 Temperature
ASD 25
ASD 30
ASD 40S
ASD 40
Minimum cut-in tempera‐
ture [°F]
40
40
40
40
Typical airend discharge
temperature during opera‐
tion [°F]
167–200
167–200
167–200
167–200
Maximum airend dis‐
charge temperature (auto‐
matic safety shut-down)
[°F]
230
230
230
230
Tab. 5 Temperature
2.5 Ambient Conditions
ASD 25
ASD 30
ASD 40S
ASD 40
Maximum elevation* [ft.]
3000
3000
3000
3000
Permissible ambient tem‐
perature [°F]
40–115
40–115
40–115
40–115
Cooling air temperature
[°F]
40–115
40–115
40–115
40–115
Inlet air temperature [°F]
40–115
40–115
40–115
40–115
Maximum relative humidi‐
ty of inlet air
* Higher altitudes are permissible only after consultation with the manufacturer
Tab. 6 Ambient Conditions
2
Technical Data
2.3
Weight
4
Service Manual Screw Compressor
ASD T Tri-Voltage
9_5721 06 USE
Summary of Contents for ASD 25
Page 1: ...Service Manual Screw Compressor ASD T Tri Voltage 9_5721 06 USE...
Page 2: ...Original instructions KKW SASD 1 00 en 01 SBA SCHRAUBEN TRI VOLTAGE T SC...
Page 8: ...List of Illustrations vi Service Manual Screw Compressor ASD T Tri Voltage 9_5721 06 USE...
Page 10: ...List of Tables viii Service Manual Screw Compressor ASD T Tri Voltage 9_5721 06 USE...