![KAESER ASD 25 Service Manual Download Page 60](http://html1.mh-extra.com/html/kaeser/asd-25/asd-25_service-manual_649423060.webp)
Fig. 23 Acknowledging/resetting messages
10
warning (yellow) LED
11
alarm (red) LED
12
«acknowledge/reset» key
Alarm message
Precondition Fault has been rectified
➤ Reset the message with the «acknowledge/reset» key.
alarm LED extinguishes.
The machine is now ready to start again.
Warning message
Precondition The danger of an alarm is eliminated.
Maintenance has been carried out
➤ Reset the message with the «acknowledge/reset» key.
warning LED extinguishes.
8
Operation
8.5
Acknowledging Alarm and Warning Messages
50
Service Manual Screw Compressor
ASD T Tri-Voltage
9_5721 06 USE
Summary of Contents for ASD 25