Fig. 1 Maximum relative humidity
T
Inlet air temperature [°F]
H
Maximum relative humidity of inlet air [%]
2.6 Ventilation
The values given are minimum guide values.
ASD 25
ASD 30
ASD 40S
ASD 40
Inlet aperture
Z
see fig‐
6.5
7.5
8.6
8.6
Forced ventilation with ex‐
haust fan:
Flow rate [cfm] at 0.4 in wc
5297
5886
7063
8240
Exhaust duct:
Dimensions [in]
25 5/8 x 25 5/8
25 5/8 x 25 5/8
25 5/8 x 25 5/8
25 5/8 x 25 5/8
Tab. 7 Ventilation
2.7 Pressure
Maximum working pressure: see nameplate
Safety relief valve blow-off setting [psig]:
Maximum working pres‐
sure [psig]
ASD 25
ASD 30
ASD 40S
ASD 40
125
155
155
155
155
175
230
230
230
230
217
232
232
232
232
Tab. 8 Safety relief valve setting
2
Technical Data
2.6
Ventilation
9_5721 06 USE
Service Manual Screw Compressor
ASD T Tri-Voltage
5