25
7.1 OUTLET REGISTER CHART
System Model
Airflow
Rate (L/s)
A
B
C
Recommended
Maximum Ceiling
Min' Floor / Ceiling
Min' Floor / Ceiling
(Adaptive Zoning Only)
Universal Heaters
KU5
KU521
785
12
5
1.5
KU530
1000
17
7
2
KU4
KU415
620
10
6
2
KU420
620
10
6
2
KU425
630
10
6
2
KU430
895
16
7
2
KU3
KU315
475
10
5
N/A
KU320
540
10
5
N/A
KU325
650
11
6
N/A
KU330
895
13
8
N/A
External Heaters
KE4
KE415 (300mm)**
498
N/A
4
N/A
KE420 (300mm)**
581
N/A
5
N/A
KE420XA (350mm)**
622
N/A
5
N/A
KE428 (350mm)**
896
N/A
8
N/A
KE428XA (400mm)**
1012
N/A
8
N/A
KE3
KE315 (300mm)**
498
N/A
4
N/A
KE320 (300mm)**
581
N/A
5
N/A
KE320XA (350mm)**
622
N/A
5
N/A
KE328 (350mm)**
896
N/A
8
N/A
KE328XA (400mm)**
1012
N/A
8
N/A
** Model and base box duct size.
Table 6
NOTE
Airflow figures are based on a total static pressure of 125 Pa for 30 & 35 models and 50 Pa for
other models.
Kaden Network 516 modules can only be used on KU4 and KU5 model heaters for adaptive zoning.