22
Kaden Installer's Manual
Ducted Gas Heaters
5.1 FAN SPEED SETTING FOR KU3, KE3 & KE4 MODELS
There are three fixed fan speed options available on KU3, KE3 and KE4 models, these are:
•
High
- “HIGH” (Factory Default)
•
Medium
- “MED”
•
Low
- “LOW”
5.1.1 To Adjust The Fan Speed
Ensure the power supply to the unit is OFF at the fixed switched socket outlet adjacent to the heater
Access the controls and change as required:
COMMON
LOW
MED
HIGH
SPEED
Fan speed high
(Factory Default Connections)
Fan speed medium
LOW
MED
HIGH
COMMON
SPEED
Fan speed low
LOW
MED
HIGH
COMMON
SPEED
Diagram 16
•
For High fan speed do not adjust
•
For Medium fan speed move terminal from “HIGH” to “MED”
•
For Low fan speed move terminal from “HIGH” to “LOW”
•
Turn the power back on once complete
IMPORTANT
When setting the fan speed
ONLY
move the HIGH, MED and LOW connection,
DO NOT
alter the
common connection.
5. FAN SPEED KU3, KE3 & KE4