12
Kaden Installer's Manual
Ducted Gas Heaters
2.3.3 Return & Supply Air POP Rotation Procedure
For KU model heaters the return air POP can
ONLY
be changed from the front side to back side. The supply air
POP can be changed from front to back or end of heater (refer to Diagram 3 page 11).
2.3.3.1 All KU3, KU4 & KU5 Models Return Air POP Rotation Procedure
1. Remove screws securing the lid and remove the lid.
2. Remove the screws securing the POP panel, blanking panel, and remove panels.
3. Swap panels to opposite sides and fasten with the same screws.
4. Secure lid with original screws.
2.3.3.2 KU315, KU320 & KU325 Supply Air POP Rotation Procedure
1. Remove the screws securing the outer POP plate and remove outer POP plate.
2. Remove the screws securing the nominated outer POP blanking plate and remove outer POP blanking plate.
3. Remove the screws securing the inner POP blanking plate and remove inner POP blanking plate.
4. Relocate and secure inner POP blanking plate in new location.
5. Relocate and secure outer POP plate and outer POP blanking plate in their new locations.
6. The pressure switch and mounting bracket will need to be swapped to the POP panel that is being exchanged.
2.3.3.3 KU415, KU420, KU425, KU430, KU330 Supply Air POP Rotation Procedure
1. Remove screws securing the lid and remove the lid.
2. Remove the screws securing the POP panel, blanking panel, and remove panels.
3. Remove gas feed tube plate and secure to alternate panel.
4. Swap panels to nominated sides and fasten with the same screws.
5. Secure lid with original screws.
6.
For the KU330
ONLY
the pressure switch and mounting bracket will need to be swapped to the POP panel
that is being exchanged.
2.3.3.4 KU521 Supply Air POP Rotation Procedure
1. Remove the screws securing the outer POP plate and remove outer POP plate.
2. Remove the insulation that is beneath the outer POP plate.
3. Remove the screws securing the nominated outer POP blanking plate and remove outer POP blanking plate.
4. Remove the screws securing the inner POP blanking plate and remove inner POP blanking plate.
5. Relocate and secure inner POP blanking plate in new location.
6. Insert the outer POP insulation in new location.
7. Relocate and secure outer POP plate and outer POP blanking plate in their new locations.
2.3.3.5 KU530 Supply Air POP Rotation Procedure
1. Remove screws securing the lid and remove the lid.
2. Remove the screws securing the POP panel, blanking panel, and remove panels.
3. Remove POP and blanking panel insulation.
4. Remove POP blanking panel and fasten in new location.
5. Insert POP and blanking insulation into their new locations.
6. Swap panels to nominated sides and fasten with the same screws.
7. Secure lid with original screws.
Summary of Contents for KU5
Page 38: ...38 Kaden Installer s Manual Ducted Gas Heaters NOTES...
Page 39: ...39 NOTES...
Page 40: ...B063650 Issue A...