Standalone operation with firmware option N/T/U300 V3
78
k4evo707en-2012-07
8.4.3 Firmware
update
Firmware updates can only be performed with the programmer 1460.
LEGIC OS Update
is not supported
Firmware updates after INI reset with programming Master or programmer
is not supported
8.4.3.1 Firmware update after INI reset with DIP switches 5 and 6
IMPORTANT
Neither the power supply nor the connection to the programming interface may be interrupted during
a firmware update
Task
LED remote
reader
LED registration
unit/illumination unit
1. Switch off the power supply at the remote reader
- The access point is blocked for the entire time
2.
Set DIP switches 5 and 6 to ON
and connect the power supply
(in the case of an uninterrupted power supply, changing the status of
DIP switches 5 and 6 has no effect)
Information:
The reader restarts every 10 s and the signaling begins
again.
LED IN1 flashes
green
2x short beeps, then
red/green flashing
(flashes only with the
compact reader)
3. Connect programmer to control unit
4. Select the firmware in the programmer and download
5. Once the firmware download has finished, this will be displayed in the
programmer
6. Switch off the power supply at the remote reader,
set DIP switches 5 and 6 to OFF
, remove the programmer and
reconnect the power supply at the remote reader
7. Remote reader is in operation again
State LED lights
up or flashes
green
Green or not lit
8. Use programmer to set the required configuration data, see
Chapter7.9.4/page 75
- Access point ready for bookings again
8.4.4
Upgrade / downgrade (crossgrade)
The programmer 1460 user manual explains how to use the V3 firmware (downgrade) instead of
the V4 firmware or vice-versa (upgrade
)
. In addition to the selection of the firmware,
the lines N, T, or U must also be determined.