PK3512_09_07 • REMOTE ACCESS CONTROLLER - 660G
9
Step 6: Connect wiring
CAUTION: Do not exceed the maximum cable length
indicated by the manufacturer of products being
connected.
!
CAUTION: Refer to the wiring diagram in Annex A, or refer
to label located inside the enclosure's cover. Follow the
applicable steps depending on what peripherals need to
be installed.
!
IMPORTANT: All peripheral wires are to be routed through
the strain relief (Q) except the power adaptor (E or F); see
step 4 for more details.
!
IMPORTANT: For peripherals, choose the appropriate
wire gauge depending on the distance between the
peripheral being installed and the controller board (B)
Refer to manufactures wire gauge installation selections.
Respect all building codes and local legislation relative
to the wiring required.
!
1.
If the controller box is to be interfaced to a fire alarm
panel, remove the jumper wire connected between pins
3 and 4 of J18 on the controller board (B) and complete
the fire panel installation as desired.
2.
If a request exit (REX) button (K) is being used, mount
the button at the desired location and run a 2-conductor,
cable from the control panel to the REX button location.
Connect as per Annex A, Table 1.
NOTE:
Refer to manufactures wire gauge installation
selections.
NOTE:
A motion detector may also be used for request exit. If
this is required, use the same connection instructions
as indicated above.
3.
If a remote unlock button (L) is being used, mount the
button at the desired location and run a 2-conductor
cable from the controller board (B) to the remote unlock
button location. Connect as per Annex A, Table 1.
NOTE:
Refer to manufactures wire gauge installation
selections.
4.
Install a 2-conductor cable from the control panel to the
location of the electric strike (H) or electromagnetic lock (I).
Connect as per Annex A, Table 1.
NOTE:
Refer to manufactures wire gauge installation
selections.
5.
Install the diode across the terminals of the electromagnetic
lock (I) or, using the crimp terminal B connectors (U)
provided in the hardware bag, install the diode across
the two wires of the electric strike (H). Do not reverse
the diode polarity, as indicated on the wiring diagram in
Annex A.
CAUTION: Diode must not be in contact with
electromagnetic lock (I) or electric strike (H), or a short
could be created. Diode ends might need to be cut
shorter.
!
NOTE:
This step is not necessary if installing Rutherford
Controls 83xx series electromagnetic lock.
6.
Following local building code requirements, mount
the electric strike (H) or electromagnetic lock (I) in the
desired location and connect as per manufacturers’
instructions. For connections into the controller box,
connect as per Annex A, table 1.
Step 7: Mounting and wiring keypad
readers
NOTE:
All keypad readers must be installed on a flat surface.
One Ingress keypad reader can be installed with the RAC 4.
Figure 10
3 x 4 Wall mount
or
2 x 6 Narrow