Mounting Keypad Reader

IMPORTANT:  The  installation  bag  supplied  with  the 
kaypad  reader  includes  screws  for  metal  panel 
installation  or  insert  and  wood  screws  for  drywall 
installation.  Use  the  relevant  screws  according  to 
which surface the keypad reader will be installed on.

!

IMPORTANT:  Refer  to  drilling  template  in  Annex  C 
to  select  the  drill  size  of  the  mounting  holes  for  the 
keypad reader.

!

1.  To install the keypad reader (G) in the desired location, use 

the template Annex C to mark the holes for the cable and 
screws.

2.  Wearing safety glasses, drill the holes in the wall according 

to the diameters indicated in the drilling template dependent 
on the type of surface the keypad reader is installed on.

3.  Connect the cable from the keypad reader (G) to the 

terminal blocks on the controller board (B) as per Annex A, 
Table 1. 

4.  Caution with keypad side table 5 or 12 volts. A jumper 

plug is installed on one of the pins. This is the default 
setting for 12 volt operation. Incorrect voltage selectable 
may cause damage refer to manufacturers specification 
document provided with reader. 

Step 8: Install strain relief bushing (for 
power adaptor only)  

One  strain  relief  bushing  (R)  is  provided  in  the  hardware 
bag  to  secure  the  power  adaptor  (E  or  F)  cable  leading  into 
the  controller  box  to  help  prevent  the  possibility  of  wire 
tampering.

or

R

Figure 12

E

F

NOTE:

  The strain relief bushing (R) provided in the hardware 

bag  has  a  movable  attached  plug.  When  the  plug  is 
removed, It leaves an opening that allows a double wire 
flat cable to be routed in.

Determine  the  routing  needed  for  the  wiring  of  the  power 
adaptor (E or F) from AC power source to the controller box. 
Remove  the  keyhole  knock-out,  on  the  upper  contour  of  the 
controller box.

To remove the knock-out, from the inner side of the controller 
box,  use  a  hammer  and  screwdriver,  and  tap  out  the  small 
metal disk.

Remove the movable plug from strain relief bushing (R), route 
the power adaptor (E or F) flat cable in. Leave a cable length 
long enough in the controller box to plug the power adaptor (E 
or F) cable into the power jack cable assembly (C) mounted in 
the inner wall of the controller box. To obtain the desired strain 
relief effect, firmly close the plug of the strain relief bushing (R) 
onto the flat cable.

Route the cable of the power adaptor (E or F) in the knock-out 
slot of the controller box. Insert the strain relief bushing (R) as 
per figure 12. The access panel of the controller box can now 
be closed

Step 9: Completing the installation

1. 

I f the panel door was removed, reinstall the door on the 

RAC 4 enclosure 

2.    Bend  the  two  tabs  of  the  panel  door  with  pliers  to  a 

maximum of 30 degrees as shown in Figure 13.

Figure 13

3.    Plug the power adaptor into the AC power source.

4.0 System Installation Overview 

(Continued)

Summary of Contents for ILCO RAC 660G

Page 1: ...INSTALLATION GUIDE Remote Access Controller 660G PK3512 ...

Page 2: ...ntroller box 7 Step 2 Identify location s for the keypad reader and required peripherals 7 Step 3 Set the desired access delay 7 Step 4 Install strain relief 7 4 2 Installation Procedures 8 Step 5 Mounting the controller box 8 Step 6 Connect wiring 9 Step 7 Mounting wiring keypad reader 9 Step 8 Install strain relief bushing 10 Step 9 Completing the installation 10 5 0 Settings and Operation 11 5 ...

Page 3: ...0 906 4526 OR Visit the Kaba Support Website http connect kabalodging com Warnings and Cautions Please read and follow all directions carefully Important Carefully inspect windows doorframe door etc to ensure that the recommended procedures will not cause damage Kaba Ilco s standard warranty does not cover damages caused by installation Important The RAC 660G should always be installed in a secure...

Page 4: ...re Side Remote Unlock Fire Alarm Ingress Keypad RAC 660G PULL FIRE Request to Exit Power Adaptor Programming M Unit Locking Device Figure 2 2 2 1 Keypad readers Two types of keypads are available G Figure 3 Figure 4 G 3 x 4 Wall mount 2 x 6 Narrow Doorframe style 2 2 2 Controller box A Enclosure with cover metallic frame which contains the controller board Knockouts are available on 3 sides of the...

Page 5: ...x Philips wood screw 8 x 1 1 4 O 4x Nylon anchor 6 10 P 4x Concrete anchor 7 9 Q 1x Strain relief connector with locking nut R 1x Strain relief bushing S 2x Diode rectifier T 5x 8 steel flat washer U 3x Crimp terminal B connector Power Adaptor includes E 1x International 12 VDC output adaptor with integrated power cable and Interchangeable AC outlet prongs or F 1x North American 12 VDC output adap...

Page 6: ...ecklist and Exploded Views Continued 3 2 Exploded View Controller Box Hardware Bag Power Adaptor Peripherals Optional Devices 5x 4x 2x 4x 4x 1x 3x Figure 7 A B D Keypad Ingress G 2 x 6 or 3 x 4 H I K J F E International North American 1x T O S U Q R P N ...

Page 7: ...9 C The controller box must be in a location sheltered against exterior elements weather hazards and dripping water Do not use cord and wall outlets for mounting of the controller box The unit must be fixed with the hardware supplied Step 2 Identify location s for the keypad reader and required peripherals Important All peripherals used by any RAC 660G user must be placed at standard height prescr...

Page 8: ...ccess it is recommended to remove the access panel before installation If needed keep it nearby to refer to the wiring label or refer to Annex A at the end of this manual CAUTION Wire routing must be according to any local building codes or legislations 2 Two types of power adaptors are available dependant of the countries where controller box is to be installed E For international applications ma...

Page 9: ...red use the same connection instructions as indicated above 3 If a remote unlock button L is being used mount the button at the desired location and run a 2 conductor cable from the controller board B to the remote unlock button location Connect as per Annex A Table 1 NOTE Refer to manufactures wire gauge installation selections 4 Install a 2 conductor cable from the control panel to the location ...

Page 10: ...he controller box to help prevent the possibility of wire tampering or R Figure 12 E F NOTE The strain relief bushing R provided in the hardware bag has a movable attached plug When the plug is removed It leaves an opening that allows a double wire flat cable to be routed in Determine the routing needed for the wiring of the power adaptor E or F from AC power source to the controller box Remove th...

Page 11: ...st choose your door 5 Hold the PALM in close proximity to D12 located near SW2 and tap Program on the PALM When complete LED D41 should be on 5 3 Reset to Factory Default In the event the Door or Site ID of the premise is changed or a problem is suspected with the current configuration the 660G will reset to default 1 Note down the current DIP switch bank SW2 settings on the controller board C as ...

Page 12: ... Functionality 2 Remote Access Controller 660G Controller Board IMPORTANT Read manual before installation or maintenance of the unit G1 B I E F 124 511689 101 RD BLK Electric Strike 506381 Electromagnetic Lock 504631 NC C N O Normally Open REX Pushbar or Button Fire Alarm Panel Contact OPENS on fire alarm Not supplied by Kaba See NOTE K Bypass Active Reset SW1 SW2 D12 D44 D43 D42 D41 D45 D46 SW3 O...

Page 13: ... WIRE M Key Override J7 3 NO L Remote J8 1 REM UNL J7 4 GND Unlock J8 2 GND K REX J8 3 REX J8 4 GND Note Connections required are dependant on system options purchased Note Part numbers indicated subject to change Please refer to ordering guide for current numbering Table 1 Table 2 PCB Status LED s LED Description D46 Keypad RED LED D45 Keypad GREEN LED D41 Initialization D42 Not Used D43 Normal O...

Page 14: ...PK3512_09_07 REMOTE ACCESS CONTROLLER 660G 14 6 0 Annex B Drilling Template ...

Page 15: ...PK3512_09_07 REMOTE ACCESS CONTROLLER 660G 15 6 0 Annex B Drilling Template ...

Page 16: ...he 660G is programmed LED D41 should be on If not program it Re program the RAC 660G 1 Power Troubleshooting 2 Keypad Troubleshooting Symptom Action All controller board B LEDs are OFF Verify that the RAC 660G controller is connected properly to the power adaptor as per Annex A Table 1 Verify that AC power is active for the wall mount power adaptor If qualified with a multi meter verify that 12VDC...

Page 17: ... LED D47 is normally on and turns off when the Fire Alarm is present Verify that the 12V_Lock output of the RAC 660G controller is connected to the COMMON of the locking device relay Unit Resets when the relay activates If the diode is installed on the Electric strike as per Annex A to unlock the door verify the polarity of the diode Verify the wiring to the locking device 4 Locking Device Trouble...

Page 18: ...port 1 800 906 4526 Customer Service T 1 877 468 3555 F 514 735 6589 General Information www kabalodging com Online Consumable Orders www keycard com To access all of our easy steps please visit our Support Website http connect kabalodging com Printed in Canada PK3512_09_07 ...