![Kaba ILCO RAC 660G Installation Manual Download Page 8](http://html.mh-extra.com/html/kaba/ilco-rac-660g/ilco-rac-660g_installation-manual_648994008.webp)
PK3512_09_07 • REMOTE ACCESS CONTROLLER - 660G
8
Determine the routing needed for the wiring of the RAC 660G
peripherals (keypads, locking mechanism, etc) and as required
select the knock-out(s) on the controller box to remove for
installation of the strain relief(s).
To remove the selected knock-out(S), from the inner side of
the controller box, use a hammer and screwdriver, and tap out
the small metal disk.
Noting the amount of wires to route into the desired location,
insert the strain relief and secure with the locking nut as shown
in figure 8. Route all wires of the peripherals, into the controller
box (A), leaving some extra length for subsequent steps.
Tighten the compression nut of the strain relief (Q) and pull on
the wires to ensure the desired strain relief effect is obtained.
CAUTION: Do not plug power adaptor into the AC outlet
before the end of installation.
!
4.2 Installation Procedures
Step 5: Mounting the controller box
1. With proper tools, install the control panel in the desired
location, using the screws, washers and required
anchors in the hardware bag.
Figure 9
A
O
P
N
T
NOTE:
For easier access it is recommended to remove the
access panel before installation. If needed, keep it
nearby to refer to the wiring label or refer to Annex A
at the end of this manual.
CAUTION: Wire routing must be according to any local
building codes or legislations.
!
2.
Two types of power adaptors are available dependant of
the countries where controller box is to be installed.
•
(E) For international applications;
mainly Europe, UK or Australia using 220 VAC to
240 VAC, 50-60 Hz
or
•
(F) For North American applications using 120 VAC,
60Hz
CAUTION: The following steps are to be done after the
appropriate power adaptor is selected, cables routed
through the strain relief bushing (R) and secured, as per
to step 8.
!
Power adaptor (E) or (F)
1.
Prior to installing the International power adaptor (E),
select the appropriate AC outlet prong from the set
depending on the standard AC power source inlet in the
country where the controller box is being installed.
2.
Fix the selected prong outlet on the International power
adapter (E).
3.
Out of the controller box
, route the wires to the AC
power source and secure the wire (recommended with
tie wraps).
4.
In the controller box
, plug the power adaptor (E or F)
cable into the power jack cable assembly (C) mounted in
the inner wall of the controller box.
4.0 System Installation Overview